A comprehensive geotechnical and geophysical assessment of the foundation sublayers in egypt’s new administrative capital
Mahmoud A. Abed, Adel Othman, Salah Shebl, Mahmoud Zayed, Mohamed H. Farag
Al-Azhar University · Egyptian Petroleum Research Institute
Key points
From the paper's conclusion- This study presents a comprehensive geotechnical and geophysical characterization of foundation sublayers in Egypt's New Administrative Capital, using thirteen Electrical resistivity Tomography (ERT) profiles with seismic velocity data from seventeen Shallow seismic refraction sites and three strategically selected Multichannel Analysis of Surface Waves (MASW) locations.
Abstract
This study presents a comprehensive geotechnical and geophysical characterization of foundation sublayers in Egypt's New Administrative Capital, using thirteen Electrical resistivity Tomography (ERT) profiles with seismic velocity data from seventeen Shallow seismic refraction sites and three strategically selected Multichannel Analysis of Surface Waves (MASW) locations. The MASW sites were selected based on geoelectric profiles that reflect the complete types of lithologic variability across the study area, ensuring representative shear wave velocity (Vs) measurements. Resistivity results delineating four major subsurface units: a variable unit of sand, clay, and rock fragments; a limestone unit, a clay unit, and a sandstone unit. Seismic data enabled the calculation of key geotechnical parameters such as: rigidity modulus, Poisson's ratio, Young's modulus, and bulk modulus, revealing zones of high competence in the northeastern and northwestern parts, and incompetent materials in the central and southwestern parts of the study area and fairy to moderately competence between them. Material competence was assessed using the concentration index, material index, and stress ratio, which collectively divided the area into zones of slightly, moderately, and highly competent materials. Bearing capacity analysis showed ultimate and allowable bearing capacity values high in the eastern and southern zones, while central regions exhibited reduced capacities. These results provide a good assessment for site-specific foundation design and highlight the value of using geoelectric and seismic methods in complex urban planning.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Geotechnical characterization and foundation competence evaluation using shallow seismic refraction: a case study from Ain Sokhna, Gulf of Suez, EgyptScientific Reports · 2026
- Identification of soil characteristics using Vp & Vs tomograms for hazard assessment: case study from Ain Sokhna area, Egypt.Scientific reports · 2026
- Site specific geophysical-geotechnical integration: correlating ERT and SPT for subsurface characterisationJournal of Petroleum Exploration and Production Technology · 2026
- Multi-criteria microzonation Hazard assessment based on the analytic hierarchy process frameworkGeomatics Natural Hazards and Risk · 2025
- GIS-Based Spatial Assessment of Urban Engineering Geological Conditions Using Borehole and Laboratory Data: A Case Study of Pavlodar, KazakhstanEng · 2026
- Assessment of the geophysical characteristics of the upper turk landslide using hvsr and masw methodsE3S Web of Conferences · 2026