Experimental analysis of elevated temperature and soiling loss on the rooftop PV modules performance under composite climatic conditions
Deepak Kumar Yadav, Satish Kumar Yadav, Vishnu Varma, Sidra Khatoon, Jyotsna Singh, Rajendra Bahadur Singh, S. M. Mozammil Hasnain, Prabhu Paramasivam,
University of Lucknow · Advanced Numerical Research and Analysis Group
Key points
From the paper's conclusion- The results reveal that elevated cell temperatures peaking at 64.0 °C caused an average daily efficiency reduction of 12.0%, with a 9.6% decline in output power directly attributable to temperature effects.
Abstract
On-field performance of a solar PV plant completely relies on solar radiation intensity and its availability. During operation, the output of a solar PV module varies from its rated capacity due to weather parameters such as ambient temperature, humidity, rainfall, wind, and dust. The primary objective of the study is to experimentally evaluate the combined effect of elevated temperature, soiling, and wind-driven convective cooling on rooftop PV performance under composite climatic conditions of North India, which are less explored compared to arid or temperate regions. During the investigation, the effects of elevated operating temperature, daily soiling accumulation, and wind-driven convective cooling on a 500 Wp rooftop PV setup monitored at five-minute intervals throughout June. The results reveal that elevated cell temperatures peaking at 64.0 °C caused an average daily efficiency reduction of 12.0%, with a 9.6% decline in output power directly attributable to temperature effects. Maximum soiling loss was calculated about 0.47% per day with a total monthly loss of 10.2% with some occasional showers cleaning the module by the end of the month. Convective heat loss from the roof mounted PV array was found to be 16.19% higher than a simulated ground-mounted system due to elevated wind exposure, contributing to a 2.27% improvement in energy yield. This study is based on a pilot-scale rooftop installation monitored for a single month. While results were normalized for broader applicability, the scope remains limited, and findings should be interpreted accordingly. The findings highlight that rooftop PV system is simultaneously affected by thermal and soiling effects, and both require explicit consideration at the design stage. Enhanced wind exposure can provide a natural and maintenance-free cooling benefit over ground-mounted systems. Site-specific cleaning schedules are essential to prevent daily dust accumulation.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Experimental and Techno-Economic Assessment of PV Soiling Losses Under Arid Climate ConditionsSustainability · 2026
- Seasonal Performance Assessment and Optimisation of a Utility-Scale Single-Axis Tracking Bifacial Photovoltaic Inverter Block in the Al-Madinah Region, Saudi Arabia, Using Multiple Analytical ToolsEnergies · 2026
- Observational study on the thermal performance of photovoltaic and cool-photovoltaic roofs during heatwaves in a semi-arid cityEnergy and Buildings · 2026
- Comparison of existing photovoltaic soiling loss models using ground measurements and reanalysis data: The case of Ben Guerir, MoroccoE3S Web of Conferences · 2026
- Advancing PV temperature modeling: comparative evaluation and a novel empirical modelApplied Thermal Engineering · 2026
- Quantifying the microclimatic feedback of citywide rooftop photovoltaic deployment in Sendai, JapanEnvironment Development and Sustainability · 2026