Experimental and simulation assessment of gamma-radiation shielding properties of the polyester polymer reinforced with WO3
Farzad Isazadeh, Akbar Abdi Saray
Urmia University
Key points
From the paper's conclusion- In this study, the shielding features of six samples of the polyester (PE)/WO 3 polymer composite against gamma rays ( 137 Cs, 22 Na, 60 Co, and 133 Ba sources) were evaluated via an experimental setup in the laboratory, using GEANT4 and MCNP Monte Carlo codes, as well as Phy-X/PSD and XCOM online programs.
Abstract
In this study, the shielding features of six samples of the polyester (PE)/WO 3 polymer composite against gamma rays ( 137 Cs, 22 Na, 60 Co, and 133 Ba sources) were evaluated via an experimental setup in the laboratory, using GEANT4 and MCNP Monte Carlo codes, as well as Phy-X/PSD and XCOM online programs. To study the structure of the composites, the X-ray diffraction (XRD) and scanning electron microscopy (SEM) analyses were conducted. Moreover, parameters such as the linear attenuation coefficient (LAC), mass attenuation coefficient (MAC), half-value layer (HVL), tenth-value layer (TVL), mean free path (MFP), effective atomic number (Z eff ), and effective electron density (N eff ) were calculated and compared for the six samples. The values of the MAC parameter for the six samples (W0, W1, W2, W3, W4, and W5) and for the experimental measurements are 0.0712 ± 0.003, 0.0714 ± 0.001, 0.0764 ± 0.002, 0.0791 ± 0.004, 0.0796 ± 0.006, and 0.0823 ± 0.003 cm 2 /g (662 keV), 0.0887 ± 0.002, 0.0889 ± 0.005, 0.0893 ± 0.007, 0.0902 ± 0.003, 0.0913 ± 0.008, and 0.0938 ± 0.002 cm 2 /g (511 keV),0.0577 ± 0.004, 0.0576 ± 0.006, 0.0568 ± 0.009, 0.0561 ± 0.002, 0.0560 ± 0.005, and 0.0551 ± 0.002 cm 2 /g (1.275 MeV),0.0615 ± 0.006, 0.0614 ± 0.008, 0.0605 ± 0.008, 0.0601 ± 0.002, 0.0596 ± 0.001, and 0.0593 ± 0.008 cm 2 /g (1.173 MeV),0.0581 ± 0.002, 0.0579 ± 0.003, 0.0572 ± 0.003, 0.0568 ± 0.003, 0.0565 ± 0.005, and 0.0560 ± 0.001 cm 2 /g (1.332 MeV), and 0.1012 ± 0.002, 0.1015 ± 0.001, 0.1035 ± 0.001, 0.1066 ± 0.005, 0.1099 ± 0.008, and 0.1201 ± 0.007 cm 2 /g (356 keV), respectively. According to the results, the W5 samples can be selected as the most effective shielding material among the samples. In addition, the experimental data and the simulated values obtained from the four mentioned programs were in good agreement, indicating that the Monte Carlo codes and online programs are reliable tools for studying nuclear reactions with high accuracy while also saving time and costs.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Development and Characterization of Polyethylene Naphthalate (PEN)/Tungsten Oxide (WO3) Composites for Gamma Radiation Shielding ApplicationsArabian Journal for Science and Engineering · 2026
- Experimental and Monte Carlo study on shielding properties of polyester/CdO polymer composite against photons using GEANT4 and MCNP codes.Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine · 2026
- Radiation Shielding Properties of Polyethylene Reinforced with PbO and CdO: Experimental and Theoretical StudyNuclear Science and Engineering · 2026
- Experimental investigation and Monte Carlo validation of PMMA-based WO3- Bi2O3 radiation shieldScientific Reports · 2026
- Computational study of hybrid DDQ/LiI/WO₃ composites for multi-radiation shielding in microelectronic applications.Scientific reports · 2026
- Integrating Experimental Measurements, WinXCom Calculations and Monte Carlo Simulations to Evaluate the Ionizing Radiation Shielding Performance of UPR/Bi2WO6 Nanocomposites.Polymers · 2026