Impression-R1 for radiological impression generation with multicenter benchmarking and prospective evaluations.
Ruixin Wang, Jinghang Wang, Yue Yin, Cong Li, Chao Zheng, Ying Zeng, Zhixue Zhang, Liye Wu,
Department of Radiology, The Second Xiangya Hospital, Central South University, Changsha, China. · College of Computer and Software, Hohai University, Nanjing, China.
Key points
From the paper's conclusion- We develop and evaluate Impression-R1, a domain-specialized large reasoning model for radiological impression generation, trained through an Imitation-Reasoning-Reinforcement pipeline integrating large-scale supervised learning, clinically conditioned reasoning, and radiology-aware reward optimization.
Abstract
Radiological impressions are critical for clinical decision-making, yet expertise is unevenly distributed, and current large language models lack domain-specific reliability. We develop and evaluate Impression-R1, a domain-specialized large reasoning model for radiological impression generation, trained through an Imitation-Reasoning-Reinforcement pipeline integrating large-scale supervised learning, clinically conditioned reasoning, and radiology-aware reward optimization. Across 11,884 cases from six institutions and three public datasets spanning imaging modalities, anatomical regions, and diseases, including cross-lingual testing on English-language benchmarks, Impression-R1 outperforms or matches state-of-the-art general-purpose models. In a 200-case head-to-head evaluation, Impression-R1 shows stronger objective agreement with institution-derived reference impressions than all participating radiologists and subjective performance within the range of less-experienced radiologists under the study evaluation framework. Prospectively, radiologists rate its reasoning and clinical relevance highly. In a randomized within-reader study of 360 interpretations, AI assistance improves report quality (adjusted difference 0.28, 95% CI, 0.10-0.46) and reduces completion time by 27% (95% CI, 19.0%-33.9%); harmlessness scores are not significantly different (adjusted difference 0.08, 95% CI, -0.11-0.28). Here we show that Impression-R1 exemplifies a clinically informed framework for developing and evaluating domain-specialized reasoning models and can improve radiological reporting quality and efficiency, while requiring continued validation before broader clinical deployment.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Comparison of AI-generated radiology impressions: a multi-stakeholder evaluationnpj Digital Medicine · 2026
- Scaling medical imaging report generation with multimodal reinforcement learningNature Communications · 2026
- Insufficient reporting quality in large language model studies in the field of radiologyInsights into Imaging · 2026
- Radiologically Relevant Clinical History Summarization with Large Language Models: A Multireader Performance StudyRadiology · 2026
- Foundation models in radiology: Development, applications, and future impact.Current problems in diagnostic radiology · 2026
- RadRef: A Reference-Free Metric for Radiology Report GenerationarXiv · 2026