Repeatable, low-drift recordings in behaving nonhuman primates using flexible microelectrodes.
Daniel P Woods, Grace M Adams, Rana Mozumder, Wenhao Dang, Andrew Y Chen, Maxime Chevée, Christos Constantinidis, Daniel L Gonzales
Department of Biomedical Engineering, Vanderbilt University, Nashville, TN, USA. · Program in Neuroscience, Vanderbilt University, Nashville, TN, USA.
Key points
From the paper's conclusion- Here we present a flexible microelectrode platform for repeated recordings in awake rhesus macaques.
Abstract
Neurophysiological recordings from nonhuman primates rely on rigid microelectrode arrays whose mechanical mismatch with brain tissue causes neuronal drift and unstable single-unit recordings. Here we present a flexible microelectrode platform for repeated recordings in awake rhesus macaques. We fabricated a 32-channel, 7-μm-thick Parylene-C array and developed a telescopic insertion method using concentric guide tubes and a retractable microwire shuttle to repeatedly deliver free-floating arrays through intact dura using standard recording chambers. Across two animals, we optimized the electrode geometry and insertion to achieve an 80% single-unit recording success rate. During an oculomotor delayed response task, we recorded stable task-responsive neurons from prefrontal and posterior parietal cortex. Compared with rigid probes in the same animals and recording chambers, flexible arrays achieved a comparable single-unit yield while reducing drift from hundreds to tens of micrometers. Our work establishes flexible microelectrodes as a practical and high-performing technology for primate neuroscience.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Curved flexible neural interfaces for laminar electrophysiology in deep-brain structures.bioRxiv · 2026
- Scalable hardware and software for high-density, multi-regional electrophysiology in non-human primates.bioRxiv : the preprint server for biology · 2026
- Umbrella-type stretchable electrode arrays for long-term neural recording.Nature communications · 2026
- Realignment of representational drift in mouse visual cortex via flexible electrode arrays.Nature biomedical engineering · 2026
- Extreme manufacturing of minimally invasive intracortical neural electrodesInternational Journal of Extreme Manufacturing · 2025
- Flexible Microneedle Array Electrode with Improved Comfort, Low Impedance, and High Performance for Electrophysiological Recording.Small (Weinheim an der Bergstrasse, Germany) · 2026