Development of response-controlled tall buildings through own-mass mobilisation
Miguel Martinez‐Paneda, A.Y. Elghazouli, Kevin Gouder, William Algaard
Arup Group (United Kingdom) · Hong Kong Polytechnic University
Key points
From the paper's conclusion- The results show reductions exceeding 70% in peak accelerations and 50% in base moments, relative to a conventional undamped configuration, while maintaining differential displacements between the movable floors and the core below 50 mm under the 50-year return wind.
Abstract
This paper describes a structural response reduction approach that, rather than adding mass as in conventional mass damping techniques, takes advantage of the large inherent mass present within a building and uses its own mass to generate large levels of reliable damping with minimal differential movements and without the need for frequency tuning. The proposed concept challenges the traditional premise of conceiving tall buildings as rigid, static entities, and exploits movements to improve performance. The underlying premise is investigated using purpose-devised aeroelastic wind tunnel tests on a dynamically scaled model of a 300-metre prototype building in which the damping system is explicitly incorporated. The results show reductions exceeding 70% in peak accelerations and 50% in base moments, relative to a conventional undamped configuration, while maintaining differential displacements between the movable floors and the core below 50 mm under the 50-year return wind. The results of the wind tunnel tests, coupled with complementary numerical studies as well seismic time-history simulations, demonstrate the considerable promise of the proposed system for significantly reducing the demands on the superstructure and foundation. This opens the door for low-carbon, high-performance tall building designs that can enable more resilient and sustainable urban development.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Performance Analysis and Optimization of Distributed Tuned Mass Damping System for Tall Buildings Under Wind‐Induced Translational and Torsional Coupling ResponseThe Structural Design of Tall and Special Buildings · 2026
- Multi‐Hazard Wind‐Seismic Vibration Mitigation of Tall Buildings Using Tuned Mass Damper Inerter (TMDI) and Structural Modification: Numerical Optimization and Experimental ValidationEarthquake Engineering & Structural Dynamics · 2026
- Sustainable Design and Energy Efficiency in Supertall and Megatall Buildings: Challenges of Multi-Criteria Certification ImplementationEnergies · 2025
- Smart Morphing Facades for Wind-Induced Vibration Control in Tall Buildings: Insights from Large-Scale Aeroelastic Wind Tunnel TestingJournal of Structural Engineering · 2026
- High Mass Ratio Tuned Mass Dampers Obtained Through Building Superelevations for Seismic RetrofitThe Eurasia Proceedings of Science Technology Engineering and Mathematics · 2026
- A Petal-Structured Vertical High-Rise Integrating Exoskeletal Load Distribution and Passive Environmental RegulationJournal for Studies in Management and Planning · 2026