Streamlined resource-efficient plasma amyloid-beta mass spectrometry assay has improved biomarker performance in preclinical Alzheimer’s disease
Yijun Chen, Xuemei Zeng, Marcos Olvera-Rojas, Kelsey R. Sewell, Anuradha Sehrawat, Jeremy Gu, Eva María Triviño-Ibañez, Patricio Alejandro Solís-Urra,
University of Pittsburgh · Universidad de Granada
Key points
From the paper's conclusion- Here, we developed a streamlined IP-MS method using a cost-effective instrument that significantly improved the efficiency of an original assay by incorporating a single immunoprecipitation step, an optimized buffer system, and approximately 75% reductions in antibody and sample volume requirements.
Abstract
Plasma amyloid-β (Aβ) peptides, alone or in ratio with p-tau217, show strong potential as Alzheimer’s disease biomarkers. While immunoprecipitation-mass spectrometry (IP-MS) is the preferred method for plasma Aβ quantification, current assays are resource- and time-intensive. Here, we developed a streamlined IP-MS method using a cost-effective instrument that significantly improved the efficiency of an original assay by incorporating a single immunoprecipitation step, an optimized buffer system, and approximately 75% reductions in antibody and sample volume requirements. Technical validation revealed excellent dilution linearity (r²>0.99), high precision (< 10% variation), enhanced sensitivity, improved Aβ recovery, and markedly increased signal-to-noise ratios. In a large cohort of cognitively normal older adults (n = 317), the plasma Aβ1-42/Aβ1-40 ratio achieved stronger concordance with Aβ-PET and superior accuracies to identify abnormal scans (AUC 0.81 vs. 0.65 for the original assay). Notably, accuracies remained high even with plasma volumes as low as 100 μL. The improved IP-MS method enables robust and simplified plasma Aβ assessment in Alzheimer’s disease, with implications for prognosis, diagnosis and intervention trials. A streamlined blood test using mass spectrometry improves measurement of amyloid-β for early Alzheimer’s disease diagnosis, requiring less sample volume and reagents while maintaining high accuracy, sensitivity and strong agreement with brain imaging.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Diagnostic performance of plasma pTau217/Aβ42 ratio and a three-zone threshold model for Alzheimer’s diseaseNeurobiology of Aging · 2025
- Analytical Methods for Fluid Biomarkers in Alzheimer’s Disease from Discovery to Clinical ImplementationInternational Journal of Molecular Sciences · 2026
- Diagnostic performance of plasma p-Tau217, p-Tau181, and p-Tau231 across the Alzheimer’s disease continuum: a network meta-analysisFrontiers in Aging Neuroscience · 2026
- Impact of preanalytical delay on the performance of plasma Aβ42, Aβ42/40, p‐tau217, and p‐tau217/Aβ42 in detecting brain amyloidosis in the ALZAN cohortAlzheimer s & Dementia · 2025
- Plasma pTau 217/β-amyloid 1–42 ratio for enhanced accuracy and reduced uncertainty in detecting amyloid pathologyBrain · 2026
- Substituting blood-based biomarkers for imaging measures in Alzheimer’s disease studies: implications for sample size and biasThe Journals of Gerontology Series A · 2026