Hypertension Research

Incentive-based digital hypertension management: a pilot randomized controlled trial comparing AI assistance and case manager support for 7-2-2 home blood pressure monitoring adherence

Tzu-Han Chen, Ching-Fen Shen, Yann-Yuh Jou, Ming-Yueh Shih, Shu-Mei Yang, Wan-Yu Yeh, Cheng-Kuo Chang, Hao-Min Cheng,

Randomised · n=1,957

Key points

From the paper's conclusion
  • These findings support the feasibility of AI-assisted hypertension self-management and provide preliminary evidence that AI-assisted support may achieve comparable changes in SBP and 7-2-2 BP monitoring adherence relative to human case management.

Abstract

This pilot randomized controlled trial (August–December 2024) evaluated the feasibility and preliminary efficacy of an incentive-based digital hypertension management platform integrating artificial intelligence (AI)-assisted education compared with human case management. A total of 1957 participants were randomly assigned in a 1:1 ratio to the AI Health Education Assistant or human case manager group. Adherence to Taiwan’s 7-2-2 home blood pressure (BP) monitoring protocol was comparable between groups (50.9% vs. 50.5%; P = 0.876), with a between-group difference of +0.4 percentage points (95% CI, −4.7 to +5.5), which met the criterion for non-inferiority against an exploratory, post hoc −5-percentage-point margin (one-sided P = 0.020). In a sensitivity analysis using all randomized participants as the denominator, the corresponding intention-to-treat adherence estimates were 37.9% and 37.4%, respectively. For the BP endpoint specified in the trial protocol, baseline-adjusted between-group differences were −0.49 mmHg (95% CI, −2.08 to 1.09) for systolic BP and 0.40 mmHg (95% CI, −0.71 to 1.51) for diastolic BP. The upper confidence bounds remained below the prespecified 3-mmHg non-inferiority margin; however, this interim complete-case analysis ( n = 292) was not powered for a confirmatory non-inferiority conclusion. In a pooled analysis of both groups, participants with elevated baseline BP (systolic BP ≥ 130 mmHg or diastolic BP ≥ 80 mmHg; n = 67) showed significant within-participant reductions in systolic BP ( − 3.0 mmHg; P = 0.002) and diastolic BP ( − 2.3 mmHg; P < 0.001). These findings support the feasibility of AI-assisted hypertension self-management and provide preliminary evidence that AI-assisted support may achieve comparable changes in SBP and 7-2-2 BP monitoring adherence relative to human case management. Trial Registration ClinicalTrials.gov Identifier: NCT07147413.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers