Making better use of patients' time: feasibility of performing self-administered vision assessments in waiting rooms.
Mehal Rathore, Panagiota Founti, Blessy Rethi, Retno Wulandari, Aneela Raja, Andrew Scott, Hari Jayaram, David P Crabb,
Department of Optometry and Visual Science, School of Health & Medical Sciences, City St. George's, University of London, London, England. · Glaucoma Service, Moorfields Eye Hospital, NHS Foundation Trust, London, England.
Key points
From the paper's conclusion- Conclusions This proof-of-concept study demonstrates that it is feasible for patients to self-administer portable vision tests in clinic waiting rooms.
Abstract
BACKGROUND: Patients often spend significant time in clinic waiting rooms. This study assessed the feasibility of using this "wasted" time to perform self-administered vision assessments directly within the waiting area. METHODS: Glaucoma patients attending routine appointments were asked to complete either a pen-and-paper (SpotChecks) or digital (PopCSF) contrast sensitivity (CS) test. Ambient illuminance, background noise, and crowd levels were recorded to assess potential environmental confounds. Test durations and patient feedback were recorded. Visual-Functioning Index-7 (VF-7) and Pelli-Robson CS (reference) test results were collected for comparison. RESULTS: Of 173 patients approached, 155 (89.6%) agreed to participate, and 151(97.4%) participants completed testing before their appointment (77/78 pen-and-paper; 74/74 digital). Environmental factors had no significant impact (all P > 0.05). Median completion times were 3.0 {2.6-4.5} minutes (pen-and-paper) and 2.5 {2.0-3.5} minutes (digital). Age did not impact the pen-and-paper test duration (P = 0.944) but weakly correlated with the digital test duration (rdigital = 0.27, P = 0.020). Functional CS scores correlated with Pelli-Robson reference measurements (rpen-and-paper = 0.81; rdigital = 0.62), age (rpen-and-paper = -0.58; rdigital = -0.37), logMAR visual acuity (rpen-and-paper = -0.42; rdigital = -0.44), and visual field mean deviation scores (rpen-and-paper = -0.54; rdigital = -0.63). Both tests were highly acceptable to patients ( > 80% on all questions). Visit durations were longer for participants (109 vs 88 min, P = 0.007), but this was attributed to consenting and related research activities rather than the tests themselves. CONCLUSIONS: This proof-of-concept study demonstrates that it is feasible for patients to self-administer portable vision tests in clinic waiting rooms. Using CS as a representative example, this approach may enable additional data collection, potentially improving patient management, clinic flow, and/or patient satisfaction.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Patient experience of and barriers to the eye examinationEye · 2026
- Test-Retest Reliability and Preliminary Validation of Smartphone-Based Threshold and Categorical loudness Measures in Home Settings.Trends in hearing · 2026
- A-21: Telephone-Based Voice Agent Cognitive Screening in Older Adults: A Feasibility and Preliminary Validity Pilot StudyArchives of Clinical Neuropsychology · 2026
- Agreement Between In‐Person and Telephone Application of the Informant Questionnaire on Cognitive Decline in the ElderlyPsychogeriatrics · 2026
- Listen to Your Heart and Mind: A Pilot Mixed‐Methods Study on Combined Screening for Raised Blood Pressure, Atrial Fibrillation, Cognitive Impairment and Hearing Loss in Older AdultsAustralasian Journal on Ageing · 2026
- Accuracy and precision of visual acuity tests: A systematic review and meta-analysis across testing strategiesmedRxiv · 2026