Fenestrated TREO® low-profile endograft in hostile access vessels.
Florian Elger, Marcello Silvano, Eberhard Grambow, Teodora Ormandzhieva, Rukiye Secer
Department of Cardiac, Thoracic and Vascular Surgery, University Medical Center Göttingen, Germany.
Key points
From the paper's conclusion- Its 19Fr low-profile delivery system may be effective for patients with low-calibre or hostile access vessels (AV), reducing trauma risk, improving limb perfusion during percutaneous procedures, and broadening FEVAR indications.
Abstract
Background: The Fenestrated TREO® is a new custom-made device for fenestrated endovascular aortic repair (FEVAR). Its 19Fr low-profile delivery system may be effective for patients with low-calibre or hostile access vessels (AV), reducing trauma risk, improving limb perfusion during percutaneous procedures, and broadening FEVAR indications. This study evaluates short- and mid-term outcomes of the device and its viability in patients with hostile AV. Materials and methods: Only patients with hostile AV treated with the Fenestrated TREO® between 2022 and 2025 at a tertiary-care university centre were included. The primary endpoint was technical success. Secondary endpoints included AV-related intraoperative procedures, short- and mid-term morbidity, mortality, reintervention rate, AV-related complications and reinterventions, and stability of target vessels (TV). A sub-analysis compared patients with AV calibre >6.3 mm (group A) and <6.3 mm (group B). Results: Twenty-eight patients were included: 18 in group A and 10 in group B. Technical success was 100%, with target vessel cannulation achieved in 99.1% (one failure). Additional intraoperative AV preparation/adjunctive procedures were required in eight patients (28.6%; 1 vs. 7, p < .001). No perioperative or late deaths occurred. AV reinterventions were required in four patients (14.3%; 2 vs. 2, p = .561). Major complications occurred in four patients (14.3%), and three of 4 AV reinterventions were observed in this subgroup. One major reintervention was necessary. Early TV instability occurred in two patients (7.1%; 1 vs. 1, p = .712). During a median follow-up of 13 months, no late deaths or reinterventions were observed. Conclusions: In patients with hostile AV, the Fenestrated TREO® graft showed high technical success rates and favourable short-term outcomes, with acceptable complication rates and excellent TV stability, aligning with results of other well-established endografts. Its low-profile design may be advantageous in complex AV anatomies. Additional intraoperative AV-related procedures mainly occurred in cases of very narrow AV (group B), while postoperative AV-related complications and reinterventions were similar between groups.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Midterm Outcomes of the Minos Ultralow Profile Endograft: Results from the Multicentre MINER Registry.European journal of vascular and endovascular surgery : the official journal of the European Society for Vascular Surgery · 2026
- Efficacy and safety of endovascular aneurysm repair for abdominal aortic aneurysms with hostile proximal neck anatomy: a single-center retrospective cohort studyFrontiers in Cardiovascular Medicine · 2026
- Long Term Target Vessel Outcomes in Patients Treated with Fenestrated Endovascular Aortic RepairEuropean Journal of Vascular and Endovascular Surgery · 2026
- Geometrical Analysis of Target Vessel Instability After FEVAR With Anaconda Stent-Graft SystemJournal of Endovascular Therapy · 2026
- Mid- to Long-Term Outcomes of an Early Experience with Fenestrated Endovascular Aortic Repair for Pararenal Versus Juxtarenal and Infrarenal Aneurysms.Annals of vascular surgery · 2026
- Endovascular Rescue of Type III Endoleak From an Abandoned Fenestration After Fenestrated Endovascular Aneurysm Repair.JACC. Case reports · 2026