A Universal Buffer System for Native LC–MS Analysis of Antibody-Based Therapeutics
Kent R. Vosper, B. Davis, Jagandeep S. Saraya, Derek K. O′Flaherty, Algirdas Vėlyvis, Siavash Vahidi
University of Guelph
Key points
From the paper's conclusion- Together, our results establish fluorinated ethylamines, in combination with ammonium acetate, as a universal volatile buffer system for native LC–MS, broadly applicable across major chromatographic modalities.
Abstract
Liquid chromatography coupled to mass spectrometry (LC–MS) is a powerful analytical technique for analyzing biological macromolecules. A long-standing challenge has been applying LC–MS at physiological pH under native conditions using volatile buffers. The predominant “buffer” used, ammonium acetate (AmAc, p K a 4.75 for acetic acid and 9.25 for ammonium), does not offer sufficient buffering capacity in the physiological pH range of 7.0–7.4. To address this, we evaluated a set of fluorinated ethylamines, 2-fluoroethylamine (MFEA), 2,2-difluoroethylamine (DFEA), and 2,2,2-trifluoroethylamine (TFEA), producing conjugate acids with p K a values of 8.9, 7.2, and 5.5, respectively, that together provide buffering across the 4.5–9.8 pH range. We show that protein separations on strong cation- and anion-exchange resins in these volatile mobile phases perform comparably to traditional nonvolatile buffers, with similar elution profiles and analyte elution ranking, albeit with slightly broader peaks. Using fully volatile gradients of pH or ionic strength, we chromatographically resolved charge variants of protein analytes such as mAbs and bovine serum albumin. For many of the eluting LC peaks, we obtained high-resolution mass spectra capable of resolving glycoforms of antibodies. Hydrophobic interaction chromatography (HIC) in volatile mobile phases preserved native separation order and further resolved drug-to-antibody ratio (DAR) species of the antibody-drug conjugate brentuximab-vedotin. For each chromatography modality we further compare innovator and biosimilar antibodies, demonstrating the reproducibility of results in the proposed volatile compounds. Together, our results establish fluorinated ethylamines, in combination with ammonium acetate, as a universal volatile buffer system for native LC–MS, broadly applicable across major chromatographic modalities.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Site-Specific N-Glycan-Resolved PK Assessment of Therapeutic Proteins Using Hybrid LBA-HRMS and LC-MS/MS.Analytical chemistry · 2026
- Sustainable UHPLC-MS/MS assay for ultra-sensitive simultaneous quantification of amoxicillin and flucloxacillin with application to a bioequivalence study.Analytical and bioanalytical chemistry · 2026
- MATRIX EFFECTS IN LIQUID CHROMATOGRAPHY-TANDEM MASS SPECTROMETRY BIOANALYSIS: MECHANISTIC FOUNDATIONS, REGULATORY EXPECTATIONS, AND PRACTICAL MITIGATION STRATEGIESAsian Journal of Pharmaceutical and Clinical Research · 2026
- Heart‑Cutting Two‑Dimensional Liquid Chromatography/High‑Resolution Mass Spectrometry and Complementary High-Performance Liquid Chromatography Methods for Comprehensive Impurity Profiling and Quality Control of Dalbavancin Hydrochloride.Journal of separation science · 2026
- Benchmarking the Performance of a Commercial Electrostatic Linear Ion Trap (ELIT) Charge Detection Mass Spectrometer For Higher-Order Antibody Aggregate AnalysisbioRxiv · 2026
- Electrostatic inversion in pH-gradient antigen affinity chromatography: The selectivity bias for deamidated trastuzumab proteoforms.Journal of chromatography. A · 2026