Chemical & biomedical imaging

Assessing Nanoparticle Detectability via 1H Chemical Shift Imaging.

Alice Santangelo, Federico Marzano, Francesca Garello, Enzo Terreno

Molecular and Preclinical Imaging Centers, Department of Molecular Biotechnology and Health Sciences, University of Turin, Piazza Nizza 44/bis, Turin 10126, Italy.

Key points

From the paper's conclusion
  • Overall, this work establishes 1H CSI as a quantitative strategy for nanoparticle evaluation and identifies formulation parameters governing intracellular detectability and clinical feasibility in nanomedicine.

Abstract

Chemical shift imaging (CSI) based on proton magnetic resonance enables label-free detection of nanocarriers, providing quantitative and spatially resolved information without the need for specific labeling tracers. Here, we evaluated the feasibility of 1H CSI to detect, quantify, and track nanosystems across in vitro, in cellulo, and in vivo settings. Five representative formulationspolymeric micelles (F127-MICs), PEGylated liposomes (Lipo-PEG), fluorinated nanoemulsions (PFCE-NEs), PLGA nanoparticles (PLGA-NPs), and paramagnetic liposomes (Lipo-Yb)were characterized in terms of physicochemical properties, proton content, and spectral signatures. High-resolution 1H NMR quantified nanoparticle uptake in RAW 264.7 macrophages, revealing formulation-dependent internalization efficiencies (0.08-1.55%). Despite low uptake fractions, intracellular proton pools (∼1-6 μmol) enabled reliable detection. Washout experiments highlighted pronounced differences in intracellular persistence: PFCE-NEs and F127-MICs retained most of their signal (≤22% reduction after 4 h), whereas Lipo-Yb and PLGA-NPs exhibited >70% signal loss. Combined 1H/19F analysis of PFCE-NEs showed that protonated components undergo biodegradation, while the fluorinated core persists. 1H CSI experiments further demonstrated that detectability depends on proton density, spectral separation from endogenous signals, and intracellular stability. Finally, in vivo proof-of-concept studies at 7 T detected intratumoral accumulation of PEGylated liposomes, supporting the translational potential of label-free proton imaging. Overall, this work establishes 1H CSI as a quantitative strategy for nanoparticle evaluation and identifies formulation parameters governing intracellular detectability and clinical feasibility in nanomedicine.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Assessing Nanoparticle Detectability via 1H Chemical Shift Imaging — Science Skim