Machine Learning-Enabled ZnS/In2O3 Heterojunction Sensors for ppb-Level Room-Temperature Hydrogen Detection.
Suraj Barala, Vikas Pandey, Amit Kumar, Ashok Kumar, Monika Kwoka-Czornik, Ankur Gupta, Mahesh Kumar
Department of Aerospace Engineering, Indian Institute of Technology Jodhpur, Jodhpur342030, India. · Department of Electronics Engineering, Indian Institute of Technology Jodhpur, Jodhpur342030, India.
Key points
From the paper's conclusion- These results establish a combined materials and data-driven strategy for robust, ambient-temperature H2 monitoring.
Abstract
Real-time, ppm-to-ppb-level detection of hydrogen (H2) remains essential for industrial safety, given its flammability and widespread use in energy applications. Portable H2 sensors, however, continue to suffer from insufficient sensitivity and reliance on elevated operating temperatures. Here, cubic bixbyite In2O3 nanocubes, synthesized by radio frequency sputtering at 600 °C, were functionalized via drop-cast decoration with ZnS nanoparticles to form an n-n heterojunction for H2 sensing at room temperature (∼32 °C). The ZnS/In2O3 architecture leverages a high surface area, oxygen vacancy-mediated adsorption, and catalytic spillover from ZnS to enhance H2 interaction and charge carrier modulation. Pristine In2O3 showed a relative response of 11.23% to 50 ppm H2, which increased to ∼23% upon optimal ZnS loading (48 wt %), with a detection limit of 86.9 ppb and response/recovery times of ∼90 s/∼488 s. To enable quantitative concentration estimation, a two-stage machine learning framework was developed using six transient response features (Smax, Trsp (90%), Trec (90%), ∫Rdt, mean dR/dt, and ∫R/s). Permutation importance identified Trec (90%), mean dR/dt, and ∫R/s as dominant predictors, while principal component analysis captured 91.8% variance with clear concentration-dependent clustering. Among four regressors evaluated via 5-fold cross-validation, Gaussian process regression achieved the best static prediction (root-mean-square error (RMSE) = 4.044 ppm, R2 = 0.945), while a 15 s sliding-window multilayer perceptron model with Bayesian-optimized hyperparameters enabled real-time tracking (RMSE = 3.837 ppm, mean absolute error = 1.263 ppm, and R2 = 0.924) across 0.5-50 ppm, with sub-5 ppm resolution well below the 4 vol % lower flammability limits. These results establish a combined materials and data-driven strategy for robust, ambient-temperature H2 monitoring.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Machine Learning-Assisted ZnIn₂ S₄ /TiO₂ Heterostructure Gas Sensor for Sensitive, Stable, and Reliable Triethylamine Detection in Complex EnvironmentsACS Applied Electronic Materials · 2026
- High-Precision Multigas Detection Based on Pd–Au Bimetallic Decorated ZnO Gas Sensors and PSO Feature OptimizationACS Applied Electronic Materials · 2026
- High-Performance MEMS Gas Sensors Utilizing an N-CQD/NiCo2O4 Composite for H2S Detection and Concentration Regression Prediction.ACS sensors · 2026
- From Empirical Ratio Tuning to Mechanistic Insight: Decoding NiO−ZnO Heterojunction Effects in Gas Sensing via Explainable Machine LearningACS Sensors · 2026
- Grain-Boundary-Facilitated Palladium Hydride Formation Enables Humidity-Tolerant Catalytic Hydrogen Sensing.Advanced materials (Deerfield Beach, Fla.) · 2026
- Metal-Organic-Framework-Derived Hollow In2O3 Microtubes with Bimetallic PdPt Alloy: Fast Trace Hydrogen Sensing with Suppressed Response Inversion.ACS sensors · 2026