Steric-Hindrance Elimination Coupled with Interfacial Enrichment for Ultrasensitive Electrochemical Biosensing.
Xiaoting Zhang, Yang Huang, Xiyu Chen, Shuo Yang, Sheng Wang, Jialiang Guo, Shengfeng Huang
Guangzhou Municipal and Guangdong Provincial Key Laboratory of Molecular Target & Clinical Pharmacology, the NMPA and State Key Laboratory of Respiratory Disease, School of Pharmaceutical Sciences, Guangzhou Medical University, Guangzhou511436, China. · School of Medicine, Foshan University, Foshan528225, China.
Key points
From the paper's conclusion- This work establishes a general electrochemical biosensing framework in which analytical sensitivity is achieved by combining steric-hindrance elimination with interfacial enrichment, providing a versatile strategy readily adaptable to diverse biological targets through replacement of the recognition element.
Abstract
Electrochemical biosensors for biological targets are fundamentally constrained by interfacial steric hindrance, which limits target accessibility in conventional capture-at-interface architectures. Herein, we report a steric-hindrance elimination coupled with an interfacial enrichment strategy for ultrasensitive electrochemical biosensing. Instead of performing molecular recognition at the electrode surface, target recognition was accomplished homogeneously on magnetic nanoparticles, followed by magnetic separation to isolate released methylene blue-labeled DNA (MB-DNA) signaling probes from bulky biological targets. This design effectively eliminates steric constraints while transforming complex recognition events into the detection of freely diffusing electroactive probes. To maximize the electrochemical output of each released probe, a MoS2-modified electrode was engineered to establish an interfacial enrichment layer through strong ssDNA-MoS2 interactions, concentrating MB-DNA at the electrode interface, and significantly increasing the number of electroactive probes available for signal transduction. Using nucleolin as a representative biological target, the biosensor exhibited a wide linear range from 10 fg/mL to 1 μg/mL with a detection limit of 5.37 fg/mL, together with excellent selectivity, reproducibility, and stability. The platform successfully discriminated plasma samples from lung cancer patients and healthy individuals and accurately differentiated nucleolin-positive lung cancer cells from normal cells. This work establishes a general electrochemical biosensing framework in which analytical sensitivity is achieved by combining steric-hindrance elimination with interfacial enrichment, providing a versatile strategy readily adaptable to diverse biological targets through replacement of the recognition element.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Tailoring the Interfacial Ionic Microenvironment of the ssDNA Brush to Quantify 250 Zeptomoles of Targets.ACS sensors · 2026
- Ytterbium Metal-Organic Framework With DNA Hydrogel Switching for ElectroChemiluminescence Biosensing.Small (Weinheim an der Bergstrasse, Germany) · 2026
- A Hybrid Phospholipid Monolayer-Based Interface for Interaction-Enhanced Electrical Detection in BiofluidsACS Nano · 2026
- A Spatial Confinement Effect-Based “Swing Probe” In Situ Entropy-Driven Assembly for the Sensitive Ratiometric Electrochemical Detection of Exosomal miRNAAnalytical Chemistry · 2025
- Programmable Electric Double Layer at Metal-Organic Framework Interfaces for miRNA Resolution.Analytical chemistry · 2026
- Modulating nanoconfined space charge for PCR-free and bisulfite-free detection of cfDNA methylation in ovarian cancer.Biosensors & bioelectronics · 2026