Distributed Fiber-Optic Biosensor with BRI Self-Compensation Based on a Step-Tapered Fiber and OFDR for ESCC Dual-Biomarker Detection.
Zitao Wang, Wei Ping, Lei Tu, Tianle Chen, Zhou Xu, Yikai Wu, Zihang Ji, Zhenjie Lu,
National Engineering Laboratory for Next Generation Internet Access System, School of Optical and Electronic Information, Huazhong University of Science and Technology, Wuhan430074, China. · Department of Thoracic Surgery, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan430030, China.
Key points
From the paper's conclusion- Here, we report a distributed fiber-optic biosensor capable of simultaneously detecting ESCC dual biomarkers with BRI self-compensation.
Abstract
Esophageal squamous cell carcinoma (ESCC) is one of the most aggressive malignancies of the digestive tract, making early detection critically important for improving patient survival and treatment outcomes. Biomarker detection is routinely employed as one of the primary modalities for the identification of ESCC. Despite advantages of high sensitivity and fast response, current optical fiber biosensors still face the main challenges of multi-biomarker detection to reduce false-positive results and compensation of the interference from bulk refractive index (BRI) variations for reliable measurement. Here, we report a distributed fiber-optic biosensor capable of simultaneously detecting ESCC dual biomarkers with BRI self-compensation. A step-tapered fiber (STF) sensor is designed with two distinct tapered regions for biomarker detection with BRI compensation. Optical frequency domain reflectometry is employed to simultaneously interrogate the two regions, enabling accurate and rapid detection of ESCC dual biomarkers in a single-shot distributed measurement. Simultaneous detection of both Cyfra21-1 and squamous cell carcinoma antigen (SCCA) biomarkers has been demonstrated within a short assay time of less than 30 min and with an average relative error of 13.8 and 15%, respectively, showing 4.5 times and 11.5 times accuracy improvement when compared to those without BRI compensation. Limits of detection of 0.07 and 0.1 ng/mL have been achieved for Cyfra21-1 and SCCA detection, respectively. The capability of multi-biomarker detection with BRI self-compensation would greatly reduce false-positive rates in ESCC diagnosis.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- A Graphene Oxide-Functionalized Fiber Optic Biosensor for Breast Cancer Biomarker Detection: Toward Developing a Highly Sensitive Multi-Fluid Diagnostic Platform.ACS sensors · 2026
- Single-fiber co-registered Raman-OCT technique with deep learning enhances in vivo oral tissue assessment.Biophotonics discovery · 2026
- Label-Free Microfiber Biosensor Reveals PD-L1 Autoantibodies as Predictive Biomarkers in Esophageal Squamous Cell Carcinoma.ACS sensors · 2026
- Portable amplification-free diagnostics of head and neck squamous cell carcinoma using SERS biosensor with machine learning-assisted classification.Analytical and bioanalytical chemistry · 2026
- Overview of Optical Fiber Biosensors for the Detection of Cancer Biomarkers in the Past DecadeACS Omega · 2026
- Label-free fiber-optic cascade sensor for rapid and ultrasensitive serum folate quantification.Talanta · 2026