ACS sensors

Self-Prognostic Electronic Skin for Reliability-Aware Wearable Sensing.

Zheng Fang, Lingji Kong, Zutao Zhang, Xiaoping Wu, Xiao Zhao, Xiangyang Chen, Ting Yang, Genshuo Liu

School of Mechanical Engineering, Southwest Jiaotong University, Chengdu610031, P.R. China. · School of Design, Southwest Jiaotong University, Chengdu611756, P.R. China.

Key points

From the paper's conclusion
  • These results establish reliability-aware wearable sensing, in which each body-state measurement is interpreted together with the operational health of the sensor itself, with potential value for long-duration applications such as health monitoring and embodied intelligence.

Abstract

Flexible wearable sensors are increasingly used for long-duration monitoring of body-state information, but they can degrade silently during operation while continuing to output physiologically plausible signals, making it difficult to determine whether an incoming measurement remains trustworthy. Here, we report a self-prognostic electronic skin platform that couples multimodal body-state sensing with autonomous sensor-health assessment. The device monolithically co-integrates piezoelectric and triboelectric transduction by origami folding into an ultrathin, six-channel wrist-mounted array (∼0.1 mm, <1 g), so that a single mechanoelectrical stream simultaneously encodes cardiovascular pulsation, wrist activity, and the device's own degradation state. A two-stage self-diagnostic framework uses an autoencoder-CUSUM pipeline to establish device-specific failure labels from degradation trajectories, followed by an LSTM-Transformer model for remaining useful lifetime prediction. Across a twenty-device cohort with a nearly sevenfold variation in lifetime, the model predicts remaining useful lifetime across the cohort's degradation trajectories with R2 = 0.95 and captures uncertainty that increases as degradation becomes more severe. In single-participant daily-use proof-of-concept testing, the system estimates physiological parameters and sensor remaining lifetime from the same stream. The predicted lifetime of a newly fabricated device remained near 100% during a representative 1.5 h segment and declined modestly to 97.2% over approximately 12 h of wear distributed across multiple days; this single-device demonstration illustrates the operation of the diagnostic channel during daily use rather than validated cross-device predictive accuracy. These results establish reliability-aware wearable sensing, in which each body-state measurement is interpreted together with the operational health of the sensor itself, with potential value for long-duration applications such as health monitoring and embodied intelligence.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Self-Prognostic Electronic Skin for Reliability-Aware Wearable Sensing — Science Skim