Shandong Key Laboratory of Micro-Nano Packaging and System Integration, College of Electronics and Information, Qingdao University, Qingdao266071, China. · State Key Laboratory of Integrated Optoelectronics, JLU Region, Key Laboratory of Advanced Gas Sensors, College of Electronic Science and Engineering, Jilin University, 2699 Qianjin Street, Changchun130012, Jilin, China.

Key points

From the paper's conclusion
  • We further extend this strategy to a portable Baijiu MeOH sensing platform for real-time methanol-risk assessment in complex liquor matrices, achieving above 98.89% accuracy in identifying samples exceeding the statutory limit.

Abstract

Accurate identification of complex gas mixtures in dynamic real-world environments is essential for environmental monitoring, food safety, and public health. However, these challenges arise mainly from overlapping response fingerprints of chemically similar hazardous analytes and the limited capability of conventional sensors to decouple multicomponent, concentration-coupled signals. Here, we report a ZnFe2O4/MoO3 mixed potential sensor array enabled by a material-device-algorithm co-design strategy. Through compositional engineering of the sensing electrodes, the array generates orthogonal cross-reactive fingerprints for six volatile organic compounds, with response fluctuation standard deviations of 0.47-2.43 mV across all analytes and a rapid response time of 12 s toward 100 ppm triethylamine. To address alcohol mixtures with strong competitive adsorption, including methanol, ethanol, and n-butanol, a CNN-BiLSTM spatiotemporal fusion model extracts multiscale features from dynamic sensing responses, enabling simultaneous mixture classification and concentration prediction. The system achieves recognition accuracies of 100 and 99.33% for the test set and independent validation set, respectively, with corresponding mean absolute errors of 1.61 and 1.62 ppm. We further extend this strategy to a portable Baijiu MeOH sensing platform for real-time methanol-risk assessment in complex liquor matrices, achieving above 98.89% accuracy in identifying samples exceeding the statutory limit. This work integrates interfacial electrochemical regulation, high-dimensional array sensing, deep-learning-enabled signal decoupling, and portable system implementation, offering a deployable route toward intelligent gas sensing in complex real-world environments.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers