From Sensor Design to Force Maps: A Systematic Evaluation of Förster Resonance Energy Transfer-Based Tension Probes.
Samet Aytekin, Sarah Vorsselmans, Giel Vankevelaer, Bert Poedts, Johan Hofkens, Jelle Hendrix, Susana Rocha
Molecular Imaging and Photonics Division, Department of Chemistry, KU Leuven, Heverlee3001, Belgium. · Dynamic Bioimaging Lab, Advanced Optical Microscopy Centre and Biomedical Research Institute, Hasselt University, Diepenbeek3590, Belgium.
Key points
From the paper's conclusion- Together, these results establish a comparative framework for interpreting FLIM-based vinculin tension measurements and provide practical design principles for selecting and engineering molecular tension probes.
Abstract
Mechanical forces transmitted through focal adhesions regulate cell behavior and disease progression, yet remain difficult to quantify at the molecular level. Genetically encoded FRET-based tension probes enable measurements of piconewton-scale forces across specific proteins in living cells, but their quantitative interpretation is highly sensitive to probe design and measurement modality. Here, we systematically compared vinculin tension sensors under identical experimental conditions, evaluating unloaded reference constructs, fluorophore pairs, mechanical sensor modules, and circularly permuted variants. Unloaded controls established a common no-force baseline and validated force-dependent readout. Among the fluorophore pairs tested, the green-red combination Clover-mScarlet-I yielded a higher unloaded FRET efficiency and hence a broader measurable dynamic range. Comparison of six mechanical sensor modules showed that the binary-response sensors FL and CC-S2 produced the largest force-dependent FRET changes and the steepest proximal-to-distal tension gradient. Circular permutation experiments revealed that fluorophore orientation has a strong, module-dependent influence on the measured FRET readout. Together, these results establish a comparative framework for interpreting FLIM-based vinculin tension measurements and provide practical design principles for selecting and engineering molecular tension probes.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- From Sensor Design to Force Maps: A Systematic Evaluation of FRET-based Tension SensorsbioRxiv · 2026
- A Step-by-Step Protocol for Quantifying Molecular Forces in Living Cells Using the Vinculin TSMod FRET Tension Sensor.Journal of visualized experiments : JoVE · 2026
- Engineering a single-fluorophore tension sensor to reveal molecule-specific force heterogeneity in vivoEuropean Heart Journal · 2026
- Live-Cell Detection of Relative Intracellular Tension Dynamics Using Non-FRET α-Actinin and α-Catenin Tension Indicators.Bio-protocol · 2026
- WHaloForce enables chemigenetic imaging of molecular tension in living cells and animals.bioRxiv : the preprint server for biology · 2026
- Direct Observation and Measurement of Membrane Tension in Xenopus laevis Animal Cap Explants Using the Mechanosensitive Dye, Flipper-TR.Methods in molecular biology (Clifton, N.J.) · 2026