Breathable, Biocompatible, Ultrathin Bilayer Epidermal Electrodes for Long-Term and Motion-Artifact-Resistant Monitoring ofHigh-Fidelity Electrophysiological Signals.
Cuiyu Liu, Bo Xue, Shengjie Liu, Weiyan Li, Huijun Kong, Xiaowen Huang, Zhaofu Zhang, Taixin Zhang,
College of Medical Information and Artificial Intelligence, Shandong First Medical University & Shandong Academy of Medical Sciences, Jinan250117, P. R. China. · Institute of Brain Science and Brain-Inspired Research, Shandong First Medical University and Shandong Academy of Medical Sciences, Jinan250117, P. R. China.
Key points
From the paper's conclusion- This work provides a new strategy for designing electrophysiological electrodes with stable, breathable, biocompatible, and low-impedance interfaces.
Abstract
Long-term monitoring of electrophysiological signals is of great importance for continuous health monitoring, disease diagnosis, and intelligent human-machine interaction. However, developing a breathable and biocompatible skin-electrode interface with low interfacial impedance for long-term and motion-artifact-resistant epidermal monitoring remains a major challenge. To address this issue, we propose a bilayer design that enables functional decoupling via synergistic structural integration. An ultrathin bilayer epidermal electrode integrating an ultrathin poly(α-lipoic acid) (PLA) adhesive layer with a porous thermoplastic polyurethane (TPU)/AgNWs conductive fibrous network (T-AgNWs film) is fabricated via coelectrospinning and subsequent concentration-induced interfacial polymerization. The ultrathin biocompatible adhesive layer ensures stable interfacial adhesion and mechanical compliance without sacrificing the breathability and conductivity of the porous network. As a result, high-fidelity electrophysiological signals including electromyography, electrooculography, electroencephalography, and electrocardiography are acquired under dynamic conditions. Reliable muscle fatigue assessment and accurate gesture recognition are further achieved, demonstrating its potential for physiological monitoring. This work provides a new strategy for designing electrophysiological electrodes with stable, breathable, biocompatible, and low-impedance interfaces.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- A Breathable Nanomesh-Textile Electrode Interface for Integrated Multimodal Monitoring.Small methods · 2026
- A Simple and Scalable Approach to High-Resolution Breathable Nanomesh Electrodes for Skin-Attachable Bioelectronics.ACS applied materials & interfaces · 2026
- Bioinspired Epidermal Electrode With Excellent Environmental Tolerance and Adhesion for Robust Electrophysiological Monitoring.Small (Weinheim an der Bergstrasse, Germany) · 2026
- Stretchable, Breathable and Skin‐conformal Nanofilm‐based Epidermal Dry Electrodes for Electrophysiological and Motion MonitoringAdvanced Functional Materials · 2026
- Mechanically robust and breathable ultrathin nanofiber/hydrogel composite electronic skin for continuous electrophysiological signal acquisition.Journal of colloid and interface science · 2026
- Cost-Effective Ultrathin SEBS-Ag Electrodes of Substrate-Regulated Microcracks for Robust Skin Electrophysiology.Small (Weinheim an der Bergstrasse, Germany) · 2026