In Vivo Cascade Cyclic Amplification Strategy for Detecting the Relative Expression of MYCN mRNA in Neuroblastoma.
Shiyao Sun, Zhenzhen Tian, Xianwei Zhang, Na Zhao, Zirong Li, Mengxin Zhang, Meng Sun, Jun Yang,
Health Commission of Henan Province Key Laboratory for Precision Diagnosis and Treatment of Pediatric Tumor, Children's Hospital Affiliated to Zhengzhou University, Zhengzhou450018, China. · Henan Key Laboratory of Rare Diseases, Endocrinology and Metabolism Center, The First Affiliated Hospital, and College of Clinical Medicine of Henan University of Science and Technology, Luoyang471003, China.
Key points
From the paper's conclusion- Collectively, this work introduces a biopsy-independent detection scheme for MYCN amplification, which holds promise for broad deployment in precision medicine and routine diagnostics.
Abstract
MYCN gene copy number in neuroblastoma tissue sections is a well-established prognostic parameter used to guide clinical risk stratification. Nevertheless, the majority of neuroblastoma cases are identified at late stages, when tumors are bulky and unresectable, precluding safe tissue sampling through surgery or core biopsy and thereby compromising the accuracy of molecular risk assessment. To address this critical diagnostic challenge, we have developed a nonbiopsy fluorescent signal conversion strategy capable of detecting MYCN amplification status without relying on tissue biopsies. The core of this method is a DNA-based biosensor based on cascade cyclic amplification (CCA), which undergoes conformational activation upon specific hybridization with intracellular MYCN or NAGK mRNA, releasing tunable fluorescent signals. The normalized fluorescence intensity ratio (referred to as the M/N ratio) quantitatively reflects the MYCN copy number status. This CCA system integrates two orthogonal functional modules-MYCN-CCA and NAGK-CCA-both exploiting elevated cytoplasmic APE1 activity in pathologically altered neuroblastoma cells as a tumor-specific molecular switch and endogenous enzymatic amplifier. APE1-mediated interactions trigger structural changes that drive the dissociation of fluorophore from quencher, generating stable and quantifiable fluorescent signals. Analytical validation demonstrates exceptional sensitivity, with detection limits of 0.52 aM for MYCN mRNA and 0.65 aM for NAGK mRNA. Importantly, the CCA platform enables precise quantification of the M/N ratio in both cell line-derived and patient-derived xenograft models, and allows rapid in situ evaluation in frozen sections of clinical neuroblastoma samples. Collectively, this work introduces a biopsy-independent detection scheme for MYCN amplification, which holds promise for broad deployment in precision medicine and routine diagnostics.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Compartmentalized Nanozyme Transduction Enables Regenerative Molecular Amplification for Multiplexed miRNA-Based Prostate Cancer StratificationbioRxiv · 2026
- Cooperative DSN-Cas12a cascade and Cu/Zr-MOF nanozyme for label-free electrochemical detection of circulating exosomal miR-21 in colorectal cancer.Mikrochimica acta · 2026
- A Topology-Programmed Circular DNAzyme Enables High-Precision Diagnosis of Metastatic Triple-Negative Breast Cancer.Analytical chemistry · 2026
- In Vivo Molecular Imaging of OGG1 Activity Using a Cyclic Cleavage-Amplified DNA Nanodevice.Analytical chemistry · 2026
- In Vivo Imaging of MicroRNA‐21 Using Catalytic Hairpin Assembly‐Enhanced Forced Intercalation ProbesAnalysis & Sensing · 2026
- Intelligent Modular Dual-Readout Architecture Driven by CRISPR/Cas13a-CHA Cascade and Machine Learning for Portable Multiplex MicroRNA Liquid Biopsy in Early Lung Cancer.ACS sensors · 2026