Flexible Sensor Array Based on Polythiophene/Cu-MOF-Derived CuO and Polyaniline/MXene Composites for Room-Temperature Detection of Hydrogen Sulfide and Ammonia.
Kuo Zhao, Yunbo Shi, Haodong Niu, Jinzhou Liu, Xiaohui Yang, Bolun Tang
School of Measurement and Control Technology and Communication Engineering, Harbin University of Science and Technology, Harbin150080, China.
Key points
From the paper's conclusion- Here, we report a flexible dual-channel sensor array coupled with a gated recurrent unit-convolutional neural network (GRU-CNN).
Abstract
Real-time detection of hydrogen sulfide (H2S) and ammonia (NH3) is important for occupational safety in humid, mixed-gas environments, yet conventional chemiresistive sensors remain limited by cross-sensitivity, humidity dependence, and poor portability at room temperature. Here, we report a flexible dual-channel sensor array coupled with a gated recurrent unit-convolutional neural network (GRU-CNN). A polythiophene/Cu-MOF-derived CuO composite (PTh/CuO) targets H2S through sulfur-affinitive CuO surface sites, whereas a polyaniline/Ti3C2Tx MXene composite (PANI/MXene) targets NH3 through PANI deprotonation and interfacial charge modulation. At 25 ± 1 °C, the optimized PTh/CuO and PANI/MXene channels exhibited responses of 87.5% to 100 ppm H2S and 189% to 100 ppm NH3, respectively, together with linear responses over 1-10 ppm (R2 = 0.997 and 0.998) and theoretical limits of detection of 73.3 and 40.4 ppb. Distinct responses were retained at 300 ppb H2S and 200 ppb NH3, with response/recovery times of 15/22 and 25/43 s, respectively. A GRU-CNN model trained using dynamic four-channel signals supported gas classification and concentration estimation across 0-10 ppm and 30%-80% relative humidity within the tested dataset; the maximum concentration-prediction mean squared errors were 0.020 for H2S and 0.015 for NH3. The channels retained 98.4% and 98.1% of their initial responses under 30° bending. Integration with a wireless wristband enabled remote signal acquisition and a wearable monitoring demonstration. This work combines chemically differentiated sensing channels, humidity-inclusive data analysis, and flexible wireless readout within a single room-temperature platform.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Ternary Heterojunction-Reinforced Room-Temperature Flexible NH₃ Sensor with Enhanced Sensitivity and Ultralow Detection LimitACS Applied Materials & Interfaces · 2026
- Interfacial‐Templated Assembly MOF‐on‐MOF Strategy: Engineering of Cu‐HHTP/NUS‐8 for High Performance H₂ S SensingAdvanced Functional Materials · 2026
- Room‐Temperature Ammonia Sensing Using a Novel CuSeO 3 /MXene Nanocomposite With Enhanced Selectivity and SensitivityAnalysis & Sensing · 2026
- An ultra-sensitive flexible room-temperature H2S sensor enabled by PANI/MXene/Cu2O ternary nanocomposites for meat spoilage monitoring.Journal of hazardous materials · 2026
- Deep Learning-Driven Selectivity Enhancement in Synergistic p-Cu₂ O/n-IGZO Gas Sensor ArraysACS Applied Electronic Materials · 2026
- Synergistic Effect of MOF-Derived Porous In2O3 and High-Entropy Alloy for Enhanced Room-Temperature Ammonia Sensing.ACS sensors · 2026