Electrochemical Biosensor Based on a Tetrahedral DNA Nanostructure and an “AND” Logic Gate-Regulated Cascade Amplification System for Parallel Detection of Dual Disease Biomarkers
Yang Li, Yifeng Zhou, Huimin Li, Yao Gao, Xiaoli Xiong, Tao Zhang, Liping Zhu, Xiurong Yang
Sichuan Normal University · Sichuan University
Key points
From the paper's conclusion- Herein, we constructed an electrochemical biosensor based on a tetrahedral DNA nanostructure and an "AND" logic gate-regulated cascade amplification system for the detection of AFP and miRNA-122.
Abstract
Hepatocellular carcinoma (HCC) is the most common form of liver cancer globally, and early diagnosis is of great significance for improving the survival rate of patients. The combined detection of important biomarkers of HCC, alpha-fetoprotein (AFP) and microRNA-122 (miRNA-122), has significant value for improving the accuracy of early diagnosis of HCC. Herein, we constructed an electrochemical biosensor based on a tetrahedral DNA nanostructure and an "AND" logic gate-regulated cascade amplification system for the detection of AFP and miRNA-122. Specifically, the product of the catalytic hairpin assembly (CHA) triggered by miRNA-122 converted the signal probe on the tetrahedral DNA nanostructure (TDN) from the double-stranded structure to the single-stranded structure. The product of the hybridization chain reaction (HCR) triggered by AFP activated the Cas12a/crRNA system. The two amplification circuits occurred in parallel on the electrode surface and in the solution, respectively. The activated Cas12a/crRNA nonspecifically cleaved the single-stranded signal probe on the TDN, resulting in significant signal changes. Since the single-stranded signal probe on the TDN can only be cleaved when both AFP and miRNA-122 are present, an "AND" logic gate with a single-signal probe output was constructed, enabling the highly sensitive combined detection of AFP and miRNA-122. The limits of detection (LOD) are as low as 4.05 fg/mL and 34.84 aM (S/N = 3), respectively. Meaningfully, this sensing platform was successfully applied to detect AFP and miRNA-122 in real human serum samples and effectively distinguished between healthy individuals and HCC patients, demonstrating its great potential in the accurate diagnosis of HCC.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Endogenous-triggered tetrahedral nanofirecracker based on SDR-CHA amplification strategies for simultaneous imaging of cancer biomarkers APE1 and miRNA-221.Talanta · 2026
- Decoupled Signal Transduction via a Non-Copper Laccase Mimic for CRISPR-Based Electrochemical Detection of Hepatocellular Carcinoma.Analytical chemistry · 2026
- Cooperative DSN-Cas12a cascade and Cu/Zr-MOF nanozyme for label-free electrochemical detection of circulating exosomal miR-21 in colorectal cancer.Mikrochimica acta · 2026
- Entropy-driven DNA circuit coupled with Cas9 trans-cleavage for dual-amplified label-free electrochemical sensing of aflatoxin B1 and lead ions.Analytical methods : advancing methods and applications · 2026
- A DNA Logic-Gated Cascade Amplification Biosensor for Highly Specific Electrochemical Detection of Circulating Tumor Cells.ACS sensors · 2026
- AND-Gated Intramolecular Confined CHA Converts Forked DNA Probes into Brushlike Assemblies for Tumor-Cell Imaging.Analytical chemistry · 2026