Laser-Reduced Graphene Oxide Electrodes as a Self-Stabilizing Scaffold for Neat Ionic Liquids in Humidity Sensing
Stefanos Matsalis, Dionysios Vroulias, Nikos Koutroumanis, George Paterakis, Labrini Sygellou, Vassilios Dracopoulos, Theophilos Ioannides, Costas Galiotis
Key points
From the paper's conclusion- Here, we report capacitive humidity sensors based on neat 1-hexyl-1-methyl-2-(3-pyridinyl)pyrrolidinium methanesulfonate ([HexNic][MeSO3]) directly immobilized within porous laser-reduced graphene oxide (LRGO) interdigitated electrodes.
Abstract
Ionic liquids (ILs) are attractive sensing materials for humidity detection because of their hydrophilicity and their highly tunable physicochemical properties. However, most reported IL-based humidity sensors require an additional immobilization matrix, such as a polymer, nanoparticle composite, or poly(ionic liquid), to stabilize the liquid phase on solid-state electrodes, thereby increasing fabrication complexity. Here, we report capacitive humidity sensors based on neat 1-hexyl-1-methyl-2-(3-pyridinyl)pyrrolidinium methanesulfonate ([HexNic][MeSO3]) directly immobilized within porous laser-reduced graphene oxide (LRGO) interdigitated electrodes. Graphene oxide (GO) was laser-reduced using a CO2 laser to produce a highly porous LRGO structure containing 92 atom % C and 8 atom % O. The IL was subsequently drop-cast onto the electrodes and retained within the porous LRGO network without the need for an additional immobilization matrix. At the optimal IL loading, the resulting sensors exhibited a sensitivity of 1650 pF/% RH, with response and recovery times of 180 and 33 s, respectively. The devices also showed very low hysteresis, with a maximum value of 1.01% RH and stable capacitive performance over 30 days. The humidity-sensing mechanism was elucidated by using complex impedance spectroscopy and attenuated total reflectance-Fourier transform infrared spectroscopy (FTIR-ATR). As a proof of concept, the sensor was further applied to respiratory monitoring and successfully distinguished between slow- and fast-breathing patterns. To the best of our knowledge, this is the first demonstration of a neat IL directly immobilized within a porous graphene-based electrode for capacitive humidity sensing without an additional polymeric or composite matrix. The approach provides a simple and scalable route to high-performance IL-based humidity sensors.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- In Situ Inorganic Salt-Enabled Laser-Induced Graphene for High-Performance Flexible Capacitive Humidity Sensing.Nanomaterials (Basel, Switzerland) · 2026
- A Leaf‐Inspired Self‐Powered Humidity Sensor With Enhanced Voltage Output and Rapid Response/RecoveryAdvanced Functional Materials · 2026
- Laser-induced graphene-based moisture generators for scalable integration and self-powered respiration monitoring.Nanoscale · 2026
- Adhesive-Free Paper-Derived Laser-Induced Graphene-Hydrogel Interfaces for Label-Free Bacterial Sensing.ACS applied bio materials · 2026
- Ionic Hydrogel-Based Solid-State Electrolyte for Versatile High-Resolution Light-Addressable Electrochemical Imaging and Sensing.ACS sensors · 2026
- Halide-mediated electrochemical functionalization of lignin for high-performance flexible humidity sensors.Bioresource technology · 2026