Dual-Reporter Signal-Off Aptamer-Based Sensing for Enhanced Vancomycin Detection
Andrea Montón-Vicente, José Quílez-Alburquerque, David Díaz Díaz, María Alba
Key points
From the paper's conclusion- Here, we report a dual-reporter EAB sensing strategy that exploits microenvironmental changes around two redox reporters within the sensing layer to improve vancomycin detection.
Abstract
The translation of electrochemical aptamer-based (EAB) sensors into real-world applications, including continuous therapeutic drug monitoring, remains limited by low sensitivity and poor stability in physiological conditions. EAB sensors typically rely on a single redox reporter covalently attached to the aptamer to transduce target-induced conformational changes into an electrochemical signal. To date, efforts to improve EAB sensor performance have focused on aptamer engineering, optimizing immobilization and backfilling strategies, and selection of redox reporters. However, strategies capable of enhancing sensitivity beyond this established single-reporter configuration remain limited. Here, we report a dual-reporter EAB sensing strategy that exploits microenvironmental changes around two redox reporters within the sensing layer to improve vancomycin detection. The sensing interface combines an Os(II)-labeled vancomycin aptamer and a surface-immobilized MB moiety covalently anchored to an alkanethiol-based mixed monolayer. We propose that the vancomycin-induced conformational change in the aptamer modulates the local redox environment of the Os(II) complex and MB. Upon target binding, the square-wave voltammetric currents of both redox reporters decrease concomitantly, resulting in a dual-signal-OFF response with enhanced analytical performance. The proposed system achieves a 19-fold lower limit of detection than the corresponding single-reporter configuration using the Os(II)-labeled aptamer. Overall, these results identify a powerful and underexplored signal-transduction mechanism, introducing a new design paradigm for enhancing the sensitivity of EAB sensors.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Engineering aptamer nanoarchitectures for electrochemical detection of Exosomal CD63.Bioelectrochemistry (Amsterdam, Netherlands) · 2026
- Designer Redox Reporters for Reactive Oxygen-Free, Nucleic Acid-Based Electrochemical Sensing.ACS sensors · 2026
- Architecture-Dependent Effects of Terminal Switching of Thiol Anchors and Methylene Blue Reporters in Electrochemical DNA-Based Sensors.ACS sensors · 2026
- Mirror-Image L-DNA Aptamers Enable Stable In Vivo Dopamine SensingJournal of the American Chemical Society · 2026
- On the Design, Fabrication, and Operation of Electrochemical Aptamer-Based SensorsACS Sensors · 2025
- General approach to achieving electrochemical aptamer-based sensor sensitivity of buffer in blood plasmanpj Biosensing · 2026