Wide-Range Capacitive Humidity Sensing with a Zn-HKUST-1 Metal–Organic Framework on Interdigitated Electrodes: Performance, Mechanism, and a Demonstration of AI-Assisted Monitoring

Syed Adil Sardar, Ruqia Bibi, Wajid Ali, Farhan Akhtar, Shahzad Iqbal, Woo Young Kim

Key points

From the paper's conclusion
  • We report a flexible capacitive humidity sensor using the metal–organic framework (MOF) Zn-HKUST-1 (Zn3(BTC)2) as the sensing layer on gold interdigitated electrodes (IDEs) patterned on polyethylene terephthalate (PET).

Abstract

We report a flexible capacitive humidity sensor using the metal–organic framework (MOF) Zn-HKUST-1 (Zn3(BTC)2) as the sensing layer on gold interdigitated electrodes (IDEs) patterned on polyethylene terephthalate (PET). Zn-HKUST-1, dispersed in NMP, was deposited to form a sensing film. The sensor operates across a broad 12–100% relative humidity (RH) range, with the largest end point-average capacitance response at 1 kHz. Within the analyzed range of 12.30–98.62% RH, the capacitance increased from approximately 0.0216 to 618.27 nF, corresponding to an end-point-average sensitivity of 7.162 nF/%RH, while the impedance magnitude decreased with increasing RH. Apparent response and recovery times were approximately 9 and 11 s under the applied humidity transitions, and the device exhibited a repeatable response over 20 humidification–desiccation cycles. Three independently fabricated devices showed a mean pointwise coefficient of variation (CV) of 2.99% at 1 kHz across 20–95% RH, while the maximum normalized hysteresis was 16.86%. The humidity-dependent response is consistent with water adsorption and dielectric/interfacial polarization, accompanied by increasing electrical losses at elevated RH. Seven-day ambient monitoring demonstrated tracking of environmental humidity changes. An offline MCUNetV3-inspired classifier achieved a mean accuracy of 96.65% for four-class humidity-state classification under leave-one-device-out testing. A separate single-participant breathing experiment demonstrated qualitative respiration-associated with fluctuations in humidity, without validated breathing classification. These findings support the potential of the Zn-HKUST-1/IDE device for flexible humidity monitoring; long-term aging and hardware-based AI inference require further evaluation.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers