Predicting Physiological-Level Glucose In Vitro with Terahertz ATR Spectroscopy: A Study of Robust Calibration
Lorenza Pia Foglia, Simon Jappe Lange, Peter Uhd Jepsen
Key points
From the paper's conclusion- The results demonstrate that glucose-induced spectral contrast can be reproducibly retrieved across liquid matrices and used for prediction at physiological concentrations.
Abstract
Noninvasive glucose sensing has been the focus of extensive optical research, yet terahertz (THz) spectroscopy remains comparatively underexplored for reliable glucose quantification at physiological concentrations. This is partly because aqueous THz measurements are strongly affected by experimental variability, which can obscure the weak glucose-induced spectral response. In this study, we investigate whether standard THz time-domain spectroscopy (TDS) in an attenuated total reflection (ATR) geometry can provide reliable, physically interpretable, and generalizable in vitro glucose quantification in liquid samples at physiological concentrations. Glucose solutions at physiological concentrations were measured in phosphate-buffered saline, deionized water, and artificial interstitial fluid to evaluate the reproducibility of the glucose-induced spectral response across optically distinct sample matrices. By combining simultaneous amplitude and phase detection with a randomized experimental protocol, differential THz-ATR spectra were used to isolate glucose-induced spectral contrast from systematic experimental effects. The differential spectra showed a reproducible glucose-dependent response across matrices, with amplitude and phase trends that followed the expected optical response of aqueous glucose solutions. Partial least-squares regression was used to assess quantitative glucose prediction and calibration generalizability. The results demonstrate that glucose-induced spectral contrast can be reproducibly retrieved across liquid matrices and used for prediction at physiological concentrations. Both pooled-matrix regression and cross-matrix calibration transfer further indicate that the calibration models can generalize across matrix conditions, with replicate repeatability remaining a key factor governing performance. To the best of our knowledge, this is the first demonstration of robust and physically interpretable in vitro glucose quantification in liquids at physiological concentrations using standard THz-TDS. These results provide a critical first step toward clarifying the role of THz spectroscopy in glucose sensing, from liquid-phase model systems to future transdermal applications.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- High sensitivity terahertz metasurface biosensor integrating plasmonic coupling and machine learning for wearable diabetes monitoringSensing and Bio-Sensing Research · 2026
- Machine Learning-Assisted Terahertz Metasurface Sensing for Diabetes Progression.IEEE transactions on nanobioscience · 2026
- Roadmap of AI-enabled terahertz spectroscopy for non-destructive testing and material characterizationNondestructive Testing And Evaluation · 2026
- Detecting absence of crystallinity in solid dosage forms with at-line terahertz process analytical technologyInternational Journal of Pharmaceutics · 2025
- Photosynthetic starch characterization using terahertz spectroscopy with a bolometer.The Analyst · 2026
- Physical stability of salbutamol amorphous solid dispersion tablets measured by terahertz spectroscopyInternational Journal of Pharmaceutics · 2026