ACS omega

A Luminescent Pt-NCN Complex Anchored onto a Polyethylene Film for Sequential Detection of Iodide and Mercury.

Josue Valdes-García, Mireille Vonlanthen, Fabián Cuétara-Guadarrama, Ernesto Rivera, Roxana Marisol Calderón-Olvera, Juan Carlos Alonso-Huitrón, David Garcia-Bassoco, Hector Luis Valdés-Negrín,

Instituto de Investigaciones en Materiales, Universidad Nacional Autónoma de México, Circuito Exterior, Ciudad Universitaria, Ciudad de Mexico C.P. 04510, México. · Instituto de Ciencias Nucleares, Universidad Nacional Autónoma de México, Circuito Exterior, Ciudad Universitaria, Ciudad de Mexico C.P. 04510, México.

Key points

From the paper's conclusion
  • These results confirm that immobilization of the Pt-NCN complex onto a polymer matrix functionalized by gamma irradiation provides a solid-state sensing platform for the sequential detection of I- and Hg2+.

Abstract

Luminescent polymers have attracted attention as solid-state sensing platforms for selective analyte recognition; however, the use of [Pt-(NCN)-Cl]-based polymers for chemosensing remains largely unexplored. Herein, luminescent platforms (PE- g -MC-1-X) based on a [Pt-(NCN)-Cl] complex (NCN = 1,3-bis-(benzimidazol-2-yl)-benzene derivative bearing two tetraethylene glycol (TEG) chains) (1) anchored onto polyethylene grafted with methacryloyl chloride (PE- g -MC) by gamma irradiation at different doses (X = 2, 4, 6, and 8 kGy) were synthesized and characterized. Among luminescent platforms, PE- g -MC-1-8kGy film was studied as a chemosensor for anions, nucleotides, and oxyanions in ethanol/water (1:1, v/v). The luminescent polymer exhibited a selective quenching response toward iodide (I-), with a quenching constant (Kq ) of 4.67(±0.49) × 103 M-1 and a limit of detection of 6.55(±0.26) ppm. Based on analyses by attenuated total reflectance Fourier-transform infrared (ATR-FTIR) spectroscopy, scanning electron microscopy coupled with energy-dispersive X-ray spectroscopy (SEM-EDS), and X-ray photoelectron spectroscopy (XPS), the binding mode of iodide was attributed to its accumulation within hydrophobic domains of TEG chains through an ion-specific effect, perturbing the electronic environment of the [Pt-(NCN)-Cl] unit. Sequential addition of mercury (Hg2+) in the presence of hydrochloric acid (HCl) restored the emission intensity, with a limit of detection of 2.40(±0.11) ppm. The luminescent material exhibited reversibility and reusability over multiple I-/Hg2+ sensing cycles. These results confirm that immobilization of the Pt-NCN complex onto a polymer matrix functionalized by gamma irradiation provides a solid-state sensing platform for the sequential detection of I- and Hg2+.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

A Luminescent Pt-NCN Complex Anchored onto a Polyethylene Film for Sequential Detection of Iodide and Mercury — Science Skim