ACS omega

Rapid On-Site Detection of Ginsenosides in Panax ginseng Using Portable Miniature Mass Spectrometry by Sodium Acetate-Enhanced Nanoelectrospray Ionization and a Same-Spectrum Same-Screening Quantification Strategy.

Longchan Liu, Yongjin Li, Haizhen Zhang, Haoyue Zhang, Wenxiang Fan, Linnan Li, Zhengtao Wang, Li Yang

The State Key Laboratory of Discovery and Utilization of Functional Components in Traditional Chinese Medicine, Institute of Chinese Materia Medica, Shanghai University of Traditional Chinese Medicine, Shanghai 201203, China. · Guizhou Medical University, Guiyang 550004, China.

Key points

From the paper's conclusion
  • Here, we developed a sodium acetate (NaOAc)-enhanced nanoelectrospray ionization (nESI) method enabling rapid, on-site ginsenoside profiling using miniature mass spectrometry (mMS).

Abstract

Ginsenosides are the major bioactive constituents in Panax ginseng (PG), exhibiting diverse pharmacological effects, including anticancer, neuroprotective, cardioprotective, and anti-inflammatory activities. On-site mass spectrometry (MS) analysis of ginsenosides plays a crucial role in PG quality control. However, owing to matrix effects, structural complexity, low volatility, poor proton affinity, and the presence of multiple glycosidic moieties, rapid analysis of ginsenosides using portable MS under ambient conditions remains challenging. Here, we developed a sodium acetate (NaOAc)-enhanced nanoelectrospray ionization (nESI) method enabling rapid, on-site ginsenoside profiling using miniature mass spectrometry (mMS). NaOAc-mediated cationization promotes efficient formation of [M + Na]+ ions, enhancing ion signal intensity. Ginsenosides were detected using full-scan MS and MS/MS, including Rb1, Rg1, Re, Rd, Rf, notoginsenoside R1, etc. For quantitative analysis of the three pharmacopoeial markers (Rb1, Rg1, and Re), a same-spectrum and same-screening (4S) strategy using structurally similar saponins as an internal standard was established. The method exhibited good linearity (5-100 μg·mL-1, R 2 > 0.99), acceptable precision (RSD < 13%), and recoveries. The limits of detection (LOD) for Rb1, Rg1, and Re were 0.10-0.20 μg·mL-1, respectively. Application of the method to PG samples of different cultivation ages revealed that the Rb1/Re ratio strongly correlated with cultivation age. This work demonstrated a practical strategy to enhance ionization efficiency and quantitative robustness in mMS and provided a feasible approach for on-site chemical assessment of herb medicines.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers