ACS omega

Matrix-Aware LC-MS/MS Quantification of Cyhexatin in Chemically Complex Herbal Matrices Using DOE-Assisted Extraction Optimization.

Jun Yeop Kim, Seung Min Lee, Woo Jae Lee, Yu Rim Ha, Jumi Lee, O Ju Lee, Hyung Min Kim, Hyunwoo Kim,

College of Pharmacy, Dankook University, Cheonan, Chungnam 31116, South Korea. · College of Pharmacy, Chungnam National University, Daejeon 34134, South Korea.

Key points

From the paper's conclusion
  • Notably, DOE-guided optimization improved cyhexatin recovery in the most challenging matrix from approximately 38% under empirical conditions to within the Codex acceptance range (70-120%).

Abstract

Matrix-dependent analytical interference remains a persistent challenge in LC-MS/MS quantification of hydrophobic pesticides in chemically complex herbal matrices. Cyhexatin, a highly hydrophobic organotin compound, exemplifies this challenge by exhibiting pronounced response variability across matrices under empirically optimized conditions. To address this limitation, we developed a matrix-aware LC-MS/MS workflow combining design-of-experiments (DOE)-assisted extraction optimization with matrix-matched calibration and surrogate internal standard (IS) normalization. Fractional factorial design was first applied to identify influential extraction parameters, followed by Box-Behnken design (BBD) to establish optimal extraction conditions in a representative challenging matrix, Angelicae Gigantis Radix. The optimized method demonstrated robust quantitative performance across Angelicae Gigantis Radix and Paeoniae Radix, satisfying Codex-aligned validation criteria for selectivity, linearity, accuracy, and precision. The method provided low-ppb analytical sensitivity, with limits of detection of approximately 3-4 ppb and a lower limit of quantification of 10 ppb. Notably, DOE-guided optimization improved cyhexatin recovery in the most challenging matrix from approximately 38% under empirical conditions to within the Codex acceptance range (70-120%). Matrix-matched calibration combined with surrogate IS normalization further reduced matrix-dependent signal variability and improved the stability of quantitative responses across matrices. The combined workflow provided robust quantitative performance in the two investigated herbal matrices and illustrated a design-oriented strategy for improving quantitative reliability under matrix-affected LC-MS/MS conditions.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers