ACS omega

Comparison of One-Dimensional and Quasi-Two-Dimensional Friction Models for Hydraulic Transient Response and Energy Dissipation in Viscoelastic Pipelines at Different Water Temperatures.

Wuhong Li, Qiang Sun, Zongku Liu, Wei Zeng

School of Civil Engineering and Transportation, Institute of Artificial Environment Control and Energy Application, Northeast Forestry University, Harbin 150040, P. R. China. · College of Water Resources and Civil Engineering, China Agricultural University, Beijing 100083, P. R. China.

Key points

From the paper's conclusion
  • These findings clarify the coupled effects of temperature and viscoelasticity on transient flow in polymer process pipelines and provide a mechanistic basis for model selection, pressure-surge control, and the safe operation of chemical-engineering piping systems.

Abstract

In chemical process systems, high-density polyethylene (HDPE) piping is widely used for conveying thermally conditioned liquids because of its corrosion resistance and operational flexibility; however, its pronounced viscoelastic response during hydraulic transients can strongly affect pressure regulation, process safety, and pipeline integrity, particularly under temperature-varying operating conditions. The temperature-dependent evolution of viscoelastic parameters, the differences between transient-flow models, and the associated energy-dissipation mechanisms remain insufficiently clarified for chemical engineering applications. In this study, transient-flow experiments in HDPE pipes at 20-40 °C were combined with numerical simulations using a one-dimensional quasi-steady friction model and a quasi-2D (quasi-two-dimensional) friction model. The first-peak occurrence time remained nearly constant at 0.1179 ± 0.0129 s, while the later response, particularly the third peak, was progressively delayed. The identified effective creep-compliance parameters increased overall with temperature and exhibited finite model-conditional admissible ranges. Model-based energy decomposition indicated that the calculated temperature-induced increase in total dissipation was governed primarily by the viscoelastic term WP , whereas the calculated frictional term Df varied comparatively little; the kinetic-elastic energy-exchange process also became shorter at elevated temperatures. The quasi-two-dimensional model did not yield a uniformly lower pressure-history RMSE, but its radial resolution of axial velocity and near-wall shear revealed model-dependent Df /WP partitions that became pronounced at 35-40 °C. These findings clarify the coupled effects of temperature and viscoelasticity on transient flow in polymer process pipelines and provide a mechanistic basis for model selection, pressure-surge control, and the safe operation of chemical-engineering piping systems.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers