From the paper's conclusion- These results indicate that oxygen- and boron nitride-doped graphene monolayers with concentrations of 6.25% and 12.5%, respectively, are promising materials for histamine-sensing applications.
Abstract
Histamine is a key immune regulator involved in allergic and inflammatory responses and is implicated in a range of immune dysregulation disorders. Reliable, continuous detection of histamine remains challenging due to its low concentrations and dynamic levels of release. In this investigation, the interaction of histamine with pristine and doped graphene monolayers, including oxygen-, boron nitride-, and silicon-doped graphene, was examined as a basis for potential biosensor materials. Density functional theory (DFT) calculations were performed to evaluate adsorption energies, defect formation energies, charge transfer, band structures, and recovery times. The results reveal that pristine graphene exhibits a weak interaction with histamine and a negligible electronic response. Silicon-doped graphene shows high sensitivity but exhibits excessively long recovery times. In contrast, graphene oxide with an oxygen concentration of 6.25% and boron nitride-doped graphene with a concentration of 12.5% display moderate adsorption energies, short recovery times, and favorable electronic responses. Notably, graphene oxide with a concentration of 6.25% exhibits band gap closure at the Fermi level following histamine adsorption. These results indicate that oxygen- and boron nitride-doped graphene monolayers with concentrations of 6.25% and 12.5%, respectively, are promising materials for histamine-sensing applications.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- A Hybrid Phospholipid Monolayer-Based Interface for Interaction-Enhanced Electrical Detection in BiofluidsACS Nano · 2026
- Flexible hydrogel sensor based on MoS₂ for highly selective dopamine detection against catecholamine cross-interferenceThe Analyst · 2025
- Nonlinear Optical Detection of β2-Microglobulin Exploiting Graphene-Enhanced Terahertz Third-Harmonic Generation.Sensors (Basel, Switzerland) · 2026
- Machine learning provides a step toward a stable electrochemical biosensor for histamine measurement in meat samplesLWT · 2025
- Simultaneous Detection of Dopamine and Xanthine in Human Sweat by Ultrasensitive MoB-MBene/PVA Sponge-like Hydrogel Grown on a Porous Nickel Substrate.ACS applied bio materials · 2026
- An Edible H₂ O₂ Biosensor for Gastrointestinal Metabolites and Peroxidase Enzyme QuantificationAdvanced Healthcare Materials · 2026