Digital Immunoassays for Sensitive Quantification of Blood Biomarkers Using Solid-State Nanopores
Liqun He, Breeana Elliott, Philipp Mensing, Kyle Briggs, Michel Godin, Jonathan Flax, James McGrath, Vincent Tabard-Cossa
University of Ottawa · University of Rochester Medicine
Key points
From the paper's conclusion- We validate the performance of this system by detecting the glial fibrillary acidic protein, a biomarker for traumatic brain injury and neurodegenerative diseases, in plasma samples and demonstrate high femtomolar-level sensitivity (∼40 pg/mL).
Abstract
Digital immunoassays enable highly sensitive detection of biomolecules, offering absolute quantification rather than relying on bulk signal intensity. We adapt a digital immunoassay scheme for a nanopore sensor, a versatile platform for single-molecule counting. Current nanopore sensors have demonstrated great progress when counting nucleic acids but struggle with proteins due to variability in translocation behavior and limited recognition strategies. While recent advancements have highlighted the promise of nanopore platforms for protein studies, precise quantification remains a challenge. Here, building on previous work, we present a nanopore-based digital immunoassay that employs gold nanoparticle-mediated molecular amplification with a single-molecule readout. This approach translates protein recognition into quantifiable DNA, enabling a precise digital assay. This assay employs a DNA NanoLock probe combined with a paramagnetic bead-based immunocapture, where the target proteins trigger a structural transformation of the NanoLock, converting their presence into a binary DNA-based signal. By incorporating AuNPs carrying hundreds of DNA proxy reporters, we effectively amplify the detectable signal by 2 orders of magnitude, significantly improving sensitivity. We validate the performance of this system by detecting the glial fibrillary acidic protein, a biomarker for traumatic brain injury and neurodegenerative diseases, in plasma samples and demonstrate high femtomolar-level sensitivity (∼40 pg/mL). Using the NanoLock probe, we further mitigate previous challenges, with reduced assay times (hours) and extended dynamic range (3-log). The self-calibrating nature of this digital approach offers robust, reproducible measurements across different nanopores, eliminating interdevice variability.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Unlocking Zeptomolar Single-Molecule Detection by Synergizing Digital Microfluidics and Digital CRISPRJournal of the American Chemical Society · 2025
- Digital Nanopore Counting Enabling Direct Identification of Trace-Level Neoantigens in Native Biological Samples.Journal of the American Chemical Society · 2026
- Confinement-enabled nanobiosensing: from chemical signal amplification to programmable single-molecule diagnostics.Chemical communications (Cambridge, England) · 2026
- Nanopore-Based Multiparametric Single-Molecule Protein Detection: From Structural Analysis to Clinical Translation.Small methods · 2026
- Digital molecular kinetics enabled by large-scale nanopore arrays for multidimensional biophysical profilingbioRxiv · 2026
- Integrated Antigen-DNA Co-Detection Using Digital Microfluidics for Improving Diagnostic Accuracy in POCT Analysis.Angewandte Chemie (International ed. in English) · 2026