High-Sensitivity Magnetic Particle Spectroscopy Platform for Precise, Specific, and Rapid Detection of Infectious Disease and Cancer-Related Biomarkers.
Hafiz Ashfaq Ahmad, Ali Dinari, Minh Phu Bui, Seungjun Oh, Masoud Rezaie, Shahla Kianamiri, Jungwon Yoon
Department of AI Convergence, Gwangju Institute of Science and Technology, Gwangju 61005, Republic of Korea. · Department of Chemistry, Jagiellonian University, Gronostajowa 2, 30-387 Cracow, Poland.
Key points
From the paper's conclusion- The high sensitivity of the developed MPS, combined with the superior specificity of monoclonal antibodies, enables precise biosensing with potential clinical relevance.
Abstract
Accurate biosensing using magnetic particle spectroscopy (MPS) depends on the interplay between biomolecular binding and the fidelity of the measurement system. MPS enables wash-free, label-free biosensing by monitoring Brownian relaxation-induced changes in magnetic nanoparticle (MNP) dynamics. However, its practical performance is often limited by a weak signal-to-noise ratio, excitation feedthrough, environmental noise, slow acquisition, and insufficient mass sensitivity. Here, a gradiometer-based MPS system incorporating noise suppression, signal integration, and harmonic detection was developed to monitor relaxation changes upon biomolecular binding. Single-core SHP-25 MNPs were conjugated with recombinant human angiotensin-converting enzyme 2 (ACE2) protein, antinucleoprotein (anti_NP) antibodies, and AS1411 aptamer to target the SARS-CoV-2 receptor-binding domain (RBD), influenza A hemagglutinin type-1, neuraminidase type-1 (H1N1) nucleoprotein, and breast cancer biomarker nucleolin, respectively. Conjugation was validated by FT-IR spectroscopy and DLS to confirm chemical attachment and hydrodynamic size modulation, while ICP-MS was used for iron-mass normalization. Relaxation changes from conjugation and target binding were recorded by MPS. The third-harmonic showed the highest sensitivity to binding-induced relaxation delays, with detection limits of 1 nM (100 fmol) for ACE2 and anti_NP and 12 nM for AS1411. Target-binding yielded statistically significant responses at concentrations as low as 5 nM for RBD, H1N1, and nucleolin. The harmonic ratio R53 (fifth/third) increased monotonically with binding, providing a mass-normalized recognition metric with reduced dependence on nanoparticle concentration. The system achieved an iron-mass sensitivity of 1 ng Fe. Comparative analysis shows that monoclonal antibody-conjugated MNPs provide greater specificity and quantitative robustness in MPS measurements than polyclonal antibodies. The high sensitivity of the developed MPS, combined with the superior specificity of monoclonal antibodies, enables precise biosensing with potential clinical relevance.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Magnetization Dynamics-Modulated Near-Infrared Mie Scattering Enables Homogeneous Femtomolar Immunosensing for Whole Blood.ACS nano · 2026
- Fingerprinting of magnetic nanoparticle stability in superimposed static and dynamic magnetic fieldsScientific Reports · 2026
- Mind the gap between functional groups and surface of magnetic nanoparticles for highly specific magnetic-based protein assays in biological mediumbioRxiv · 2026
- A localization and quantification method of Fe 3 O 4 magnetic nanoparticles based on MRX and Unscented Kalman FilterMeasurement Science and Technology · 2026
- Multiresonant Membrane Metasurfaces for Multifunctional Molecular Absorption Sensing and Real Time Biochemical Tracking.Advanced materials (Deerfield Beach, Fla.) · 2026
- Continuous mass photometry by single-molecule trappingNature Methods · 2026