Better Together Than Apart: Degradation of Emerging Contaminants in Concentrated Streams Using UV/Sulfite/Iodide and UV/Hydrogen Peroxide Treatment Trains.
Iván Sciscenko, Agustín París-Reche, Ana Agüera, Patricia Plaza-Bolaños, Claudio Minero, Marco Minella
Department of Chemistry, University of Turin, Via Pietro Giuria 7, Turin 10125, Italy. · Department of Chemistry and Physics, University of Almeria, Carretera de Sacramento s/n, Almería 04120, Spain.
Key points
From the paper's conclusion- This work is one of the first to offer valuable information on the degradation of PFAS and non-PFAS pollutants by the aforementioned treatment trains, especially in concentrated wastewater treatment streams.
Abstract
This study evaluates the performance of homogeneous UV-based advanced reduction processes (ARPs) and advanced oxidation processes (AOPs), applied individually and in sequential treatment trains as a largely unexplored approach for the degradation of aqueous contaminants. UVC/SO3 2- and UVC/SO3 2-/I- were the reference ARPs, while UVC/H2O2 was used as the reference AOP. A mixture of three model contaminants was used in all cases, consisting of perfluorooctanoic acid (PFOA, as a model perfluoroalkyl substancePFAS), ibuprofen, and benzoic acid. The UVC/SO3 2- treatment achieved 70% defluorination of 100 μM PFOA after 24 h of irradiation, while nearly complete defluorination was obtained with UVC/SO3 2-/I- in the same period. Benzoic acid exhibited the fastest degradation rates with both ARPs (k obs = 3.9 × 10-1 min-1, 100 μM concentration), whereas ibuprofen was considerably slower, being comparable to its direct photolysis (k obs = 2.9 × 10-2 min-1, 100 μM concentration). In contrast, the UVC/H2O2 process efficiently mineralized benzoic acid and ibuprofen (>99% within 2 h) but showed negligible degradation of PFOA (<1% in 2 h). The treatment trains (AOP → ARP and ARP → AOP) were decisively more efficient when dealing with the pollutant mixture degradation in the presence of scavengers. With the AOP → ARP approach, for matrices containing 50 mg L-1 of humic acids, the UVC/H2O2 pretreatment led to faster PFOA defluorination rates than ARPs alone (65% and 5% in 2 h, respectively). The inverse configuration, ARP → AOP, allowed the mineralization of PFOA, a result that could not be achieved when either ARPs or the AOP were applied individually. Experiments in simulated retentate wastewater, containing 1 μM of each contaminant and high concentration of anions and organic matter, were consistent with the preliminary results. This work is one of the first to offer valuable information on the degradation of PFAS and non-PFAS pollutants by the aforementioned treatment trains, especially in concentrated wastewater treatment streams.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Matrix-driven pathways enabling complete defluorination of 6 : 2 FTCA in simulated alkaline IEX regeneration wastewater: comparison of UV/S and UV/PS with mechanistic and kinetic insights.RSC advances · 2026
- Tuning reactive species formation in dithionite-based advanced reduction processes for the degradation of carbamazepine and perfluorooctanoic acid.Water research · 2026
- Evaluation of Perfluorooctanoic Acid (PFOA) Degradation in Synthetic Water Using Advanced Oxidation Processes Based on O3, H2O2, and UV LightMolecules · 2026
- Photocatalytic removal of perfluorooctanoic acid pollutant from water via reverse fluorination strategy.Journal of hazardous materials · 2026
- Photocatalysis and Electro-Oxidation for PFAS Degradation: Mechanisms, Performance, and Energy EfficiencyCatalysts · 2026
- Kinetics and mechanism of TiO₂ and ZnO based advanced oxidation processes for degradation of emerging contaminant levofloxacinZeitschrift für Physikalische Chemie · 2026