Model-Driven Discovery of Highly Sensitive Nanocolumnar NiO Electrochemical Glucose Sensors.
MohammadAli Maleki Bigdeli, Jennifer Bruce, Abebaw B Jemere, Kenneth D Harris, Wylie Stroberg
Department of Mechanical Engineering, University of Alberta, Donadeo Innovation Centre for Engineering, 116 St NW, Edmonton, Alberta T5K 1S6, Canada. · Quantum and Nanotechnologies Research Centre, National Research Council Canada, 11421 Saskatchewan Dr NW, Edmonton, Alberta T6G 2M9, Canada.
Key points
From the paper's conclusion- We identify a slanted-post morphology deposited at 72.5° as the optimal design for maximizing glucose electro-oxidation, and we find that physical electrodes formed with similar geometries were approximately 25% more sensitive to glucose than those formed with the vertical post morphology previously considered to be the optimum (i.e., 1.38 mA/mM·cm2 vs 1.12 mA/mM·cm2).
Abstract
Nanostructured NiO electrodes fabricated using glancing angle deposition (GLAD) are promising platforms for nonenzymatic electrochemical glucose sensing, owing to their high surface area and tunable morphology. With GLAD, adjusting the deposition angle and substrate rotation rate can significantly affect electrochemical performance; however, identifying optimal GLAD structures for specific use cases is still largely experimental, relying on trial and error. Here, we develop a multiscale modeling framework that links the GLAD film growth process to glucose electro-oxidation performance by combining on-lattice kinetic Monte Carlo (kMC) simulations with morphology characterization and a coupled reaction-diffusion electrochemical model. Key morphological features, including surface area, porosity, and directional tortuosities, are quantified from kMC-generated structures across a wide range of GLAD geometries, such as slanted posts, helical shapes, and vertical nanocolumns. These features are then incorporated into a homogenized porous electrode model for glucose electro-oxidation on Ni-based catalysts. The model clarifies how the trade-off between surface area and mass transport governs electrode sensitivity. We identify a slanted-post morphology deposited at 72.5° as the optimal design for maximizing glucose electro-oxidation, and we find that physical electrodes formed with similar geometries were approximately 25% more sensitive to glucose than those formed with the vertical post morphology previously considered to be the optimum (i.e., 1.38 mA/mM·cm2 vs 1.12 mA/mM·cm2). Beyond glucose, this modeling workflow provides general guidelines for designing GLAD-fabricated electrodes for other biosensing targets and for electrochemical applications, including energy conversion and hydrogen generation.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Mask‐Free Electro‐Addressable Localization of GOx@ZIF‐8 on Prussian Blue Microelectrodes for Glucose BiosensingSmall · 2026
- Kinetic model for BTX adsorption on NiO surface in resistive MEMS gas sensors: determination of the energy components of the model.Physical chemistry chemical physics : PCCP · 2026
- Copper-Based MOF Derivative with Enhanced Electrocatalytic Activity for Highly Sensitive and Ultrafast Detection of Salivary GlucoseAnalytical Chemistry · 2026
- Dendritic Fe2O3-rGO nanoarchitectures for electrochemical uric acid sensing coupled with explainable machine learning-driven sensor analytics.Nanoscale advances · 2026
- Defect-engineered lignite-derived carbon/NiCo2O4 interfaces enable oxygen-vacancy-mediated nonenzymatic glucose sensing in serum samples.RSC advances · 2026
- Benzimidazole-Regulated 1D 4-Fluorosalicylic Acid MOF Composite Material Design and Its Application in Glucose Sensing.Molecules (Basel, Switzerland) · 2026