ACS biomaterials science & engineering

A Comparative Study of Ultraviolet Radiation and Steam Autoclave as Sterilization Methods of Zinc-Based Materials for In Vitro Assays.

Francisca M Seabra, Martin Balog, Martina Takáčová, Yujie Zhao, Peter Krížik, Eliška Švastová, Karolína Pánová, Vojtěch Hybásek,

Institute of Materials and Machine Mechanics, Slovak Academy of Sciences, Bratislava84513, Slovakia. · Biomedical Research Center, Slovak Academy of Sciences, Bratislava84513, Slovakia.

Preclinical

Key points

From the paper's conclusion
  • In the present work, two widely available sterilization methods, steam autoclave (SA) and ultraviolet radiation (UVR), are used with four different Zn-based materials: cast and extruded pure Zn, a Zn-0.5Mg alloy, and a Zn + ZnO composite.

Abstract

In the present work, two widely available sterilization methods, steam autoclave (SA) and ultraviolet radiation (UVR), are used with four different Zn-based materials: cast and extruded pure Zn, a Zn-0.5Mg alloy, and a Zn + ZnO composite. Before and after sterilization, the materials are compared regarding surface analysis, biological medium extraction, and biological response. The results show that while UVR is a safe choice, not significantly modifying the sample, SA leads to surface oxidation, influencing both extraction and biological response. This study concludes that SA should be avoided as a sterilization method for all Zn-based materials.