ACS Applied Polymer Materials

An AIE-Active Cross-linker as a Built-in Optical Probe of Mechanical Damage and Recovery in Coordination-Covalent Dual-Cross-linked Hydrogels

Mingyan Xie, Yuekai Huang, Zhixian Dong, Jinbao Xu, Caihong Lei

Key points

From the paper's conclusion
  • Here, we report a dual-cross-linked hydrogel that integrates a tetraphenylethylene (TPE)-based aggregation-induced emission (AIE) cross-linker (TAUPE) and Zr4+-carboxyl coordination bonds in a poly(acrylic acid-co-lauryl methacrylate) network, in which the TAUPE junctions serve as both permanent network points and built-in fluorescent reporters, whereas the Zr4+-carboxyl coordination bonds act as

Abstract

Dynamic noncovalent cross-links impart hydrogels with toughness and adaptability, yet optically tracking how such networks are damaged by and recover from large-deformation loading remains challenging. Here, we report a dual-cross-linked hydrogel that integrates a tetraphenylethylene (TPE)-based aggregation-induced emission (AIE) cross-linker (TAUPE) and Zr4+-carboxyl coordination bonds in a poly(acrylic acid-co-lauryl methacrylate) network, in which the TAUPE junctions serve as both permanent network points and built-in fluorescent reporters, whereas the Zr4+-carboxyl coordination bonds act as sacrificial cross-links. Upon uniaxial stretching to 300% strain, the dual-cross-linked hydrogel exhibits faster fluorescence attenuation, larger hysteresis, and impaired fluorescence recovery after unloading (71% versus 94% for the covalent-only analogue after 180 min at 25 °C). Annealing at 60 °C restores up to 75% of the original emission, accelerates the recovery kinetics more than 3-fold, yet raises the recovery plateau only modestly (from 71% to 75% after 180 min), indicating that the reorganization is thermally activated in rate but thermodynamically limited in extent. The optical and mechanical recovery pathways are decoupled. Upon mild annealing, the damaged network transiently over-recovers its pristine load-bearing capacity (σ/σ0 up to 1.28; U/U0 up to 1.34), while a substantial fraction of the fluorophores remains in an unrecovered local environment. This decoupling demonstrates that the fluorescence readout reports locally trapped damage rather than the bulk connectivity of the network, offering a multiscale view of damage and healing in dynamically cross-linked materials. As a proof of concept, the strain-responsive fluorescence enables rewritable information encryption and direct visualization of mechanical damage.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers