科研速览 · Science Skim继续刷下去 · Keep skimming →
◆ ACS Applied Polymer Materials2026-01-10· Self-healing hydrogels

Poly(vinyl alcohol) (PVA)/Graphene Oxide (GO)/Vitamin A Palmitate (VAP) Hydrogels for Wound Care: Integrating Mechanical Robustness, Photoprotection, and Enhanced Bioactivity

Cristian Escobar, Toribio Figueroa, Luisbel González, Isleidy Ruíz, Claudio Aguayo, Jorge R. Toledo, Álvaro R. Ruiz Garrido, Fernanda Larenas-Muñoz, Katherina Fernández

原始摘要(英文原文)· Original abstract
This work reports chemically cross-linked poly(vinyl alcohol) (PVA) hydrogels cofunctionalized with graphene oxide (GO ≤ 0.2 wt %) and vitamin A palmitate (VAP ≤ 0.2 wt %) as a single platform wound dressing that couples multiple functionalities: mechanical reinforcement, photoprotection, tunable swelling and retinoid delivery. The GO/VAP loading significantly enhances the mechanical properties of neat PVA ( E c = 15.8 ± 0.5 kPa; failure strain 0.51), transforming it into highly compressible networks with E c up to 57.4 ± 1.0 kPa, compressive stresses up to 327 kPa and strains of 0.64–0.76 without fracture, and tensile strains up to 2.6 at 68 kPa, outperforming previously reported PVA/GO hydrogels. The equilibrium swelling ratio was tuned from 120 to 222% by varying GO and VAP contents, which correlates with a transition from mixed diffusion/relaxation to predominantly diffusion-controlled VAP release (as described by Peppas–Sahlin fits, R 2 = 0.998–0.999). A key finding of this system is the marked extension of VAP photostability upon incorporation into GO-containing PVA matrices: the characteristic UV–C photodegradation time increases from 3.6 × 10 2 min for free VAP to 1.2 × 10 3 min in GO/VAP formulations (3.3-fold increase), while still retaining 71–86% of the initial absorbance at 330 nm after 1 week versus 59% for VAP alone. PVA-GO 0.1% /VAP 0.2% and PVA-GO 0.2% /VAP 0.2% release 55 and 44% of VAP within 150 min, and their cumulative release at 58 h reaches 89 and 72%, respectively. In contrast, the sample without GO (PVA-VAP 0.2% ) release only 35%. All hydrogels are noncytotoxic to human dermal fibroblasts (HDF) (viability ≥ 86%, up to 122%), nonhemolytic (HR < 2%) and nonirritant in vivo (PII = 0). The PVA-GO 0.2% /VAP 0.2% formulation promotes near-complete closure (in a scratch test at 48 h) and organized collagen in a porcine full-thickness wound model, thus underscoring the originality of integrating GO and VAP within a single PVA matrix for multifunctional wound care.
读原文 · Read the paper ↗

AI 追问PRO

登录后使用 AI 追问

讨论区

登录后参与讨论

相关论文 · Related

Poly(vinyl alcohol) (PVA)/Graphene Oxide (GO)/Vitamin A Palmitate (VAP) Hydrogels for Wound Care: Integrating Mechanical Robustness, Photoprotection, and Enhanced Bioactivity — 科研速览 Science Skim