Binary-Crosslinked Alginate/Zwitterionic Interpenetrating Polymer Network Coatings for Lubricious and Antifouling Urinary Catheters.
Young Ho Seo, Dong Uk Lee, Ji Ho Choi, Jeong Sang Son, Kang Bin Kim, Woojin Kim, Dong Yun Lee, Dong Yun Choi
Biomedical Manufacturing Technology Center, Korea Institute of Industrial Technology, Yeongcheon38822, Republic of Korea. · User Convenience Technology R&D Department, Korea Institute of Industrial Technology, Ansan15588, Republic of Korea.
Key points
From the paper's conclusion- Here, we report an alginate/sulfobetaine methacrylate-based zwitterionic interpenetrating polymer network (Alg-ZW IPN) that integrates a binary crosslinker system into the IPN architecture by pairing a short-chain crosslinker, N,N′-methylenebisacrylamide (MbAm), with a long-chain crosslinker, poly(ethylene glycol) dimethacrylate (PEGDMA).
Abstract
Hydrophilic hydrogel coatings can mitigate catheter-associated infections and friction-induced mucosal trauma during urinary catheterization by providing hydration-driven lubrication and antifouling surfaces. Here, we report an alginate/sulfobetaine methacrylate-based zwitterionic interpenetrating polymer network (Alg-ZW IPN) that integrates a binary crosslinker system into the IPN architecture by pairing a short-chain crosslinker, N,N'-methylenebisacrylamide (MbAm), with a long-chain crosslinker, poly(ethylene glycol) dimethacrylate (PEGDMA). In the binary crosslinked IPN (Alg-ZW BIPN), MbAm establishes dense local junctions for structural integrity, while PEGDMA spans the interjunction domains to mechanically bridge the network, confine alginate chains, and stabilize Ca2+-alginate coordination. This architecture redistributes mechanical stress across length scales, thereby improving coating durability. The Alg-ZW BIPN coating exhibited ultralow friction, with a friction coefficient of 0.01-0.02, and maintained 49% lower friction than MbAm single crosslinker coatings. In catheter insertion tests using a standard vascular phantom, the coating reduced insertion force by up to 75% compared with uncoated catheters. The coating also inhibited Escherichia coli adhesion by 97.4% relative to uncoated substrates and showed excellent biocompatibility, with a hemolysis ratio of 0.17% and >95% endothelial cell viability after 24 h. Overall, the Alg-ZW BIPN design provides a general and scalable route to mechanically robust, lubricious, and antifouling hydrogel interfaces for indwelling medical devices.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Antimicrobial zwitterionic hydrogel coatings for kidney disease-associated catheters: current challenges and advances.Biomaterials science · 2026
- Photoinitiated Regulated Silver-Releasing Zwitterionic Hydrogel Coating for Antibacterial, Antifouling, and Thrombus-Resistant PVC Catheters.ACS omega · 2026
- Enzyme-Triggered Polymerization of Lubricant and Antibacterial Sodium Alginate-Based Hydrogel Coating on Diverse SubstratesACS Applied Polymer Materials · 2026
- Robust, Universal, and Reproducible Zwitterionic Hydrogel Medical Coatings Enabled by Cross-Linkable and Graftable Silatrane ChemistryACS Applied Polymer Materials · 2025
- Zwitterionic Coatings for Urinary Catheters: Current Progress, Design Principles and Translational Challenges.ACS omega · 2026
- Robust and durable zwitterionic hydrogel coating with catechol-Cu2+ coordination for antithrombotic and antibacterial blood-contacting devicesBioactive Materials · 2026