Impact of Microporous Layer Composition on the Water Content in the Membrane Electrode Assembly of Polymer Electrolyte Fuel Cells
Kinanti Aliyah, Anne Berger, Timon Lazaridis, Christian Appel, Christian Prehal, Andreas Menzel, Manuel Guizar-Sicairos, Glen J. Smales,
Paul Scherrer Institute · Technical University of Munich
Key points
From the paper's conclusion- The water content in the membrane, catalyst layers (CL), and MPLs was explored using operando scanning small- and wide-angle X-ray scattering (S/WAXS).
Abstract
High Resolution Image Download MS PowerPoint Slide Polymer electrolyte fuel cells are paramount for future emission-free mobility. One of the vital challenges for prospering commercialization of PEFCs is water management in the cells. A microporous layer (MPL) is typically positioned between the gas diffusion layer (GDL) and the catalyst layer (CL) to boost the cell performance and facilitate water management. In this study, three different MPLs were investigated, namely, carbon black-based MPLs with different PTFE binder contents (20 wt % PTFE as a base case and 40 wt % PTFE), as well as perforated MPLs with micron-sized pores coated on the same GDL-Substrate (Freudenberg H14). The water content in the membrane, catalyst layers (CL), and MPLs was explored using operando scanning small- and wide-angle X-ray scattering (S/WAXS). At T cell = 80 °C, relative humidity = 100%, p abs = 3 bar, the MPL with larger pores exhibits slightly higher performance than the base case, while a considerably lower cathode CL and MPL saturation levels were observed for the MPL. In contrast, the MPL with higher amounts of PTFE binder shows lower performance than the base case, with considerably higher cathode CL and MPL saturation levels. 3D representations of how the pores could be filled in the cathode CLs were obtained from operando SAXS profiles using representative structure modeling for the different materials and operating conditions.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Modeling Impact of Crack Density on the Performance of the Microporous Layer in PEMFCs.ACS omega · 2026
- Microporous layer (MPL) material structural modifications for enhanced efficiency and durability of proton exchange membrane fuel cells (PEMFCs): Toward sustainable maritime energy solutionsNext Materials · 2026
- Hierarchical Interfaces Structure Enabling Adaptive Gas–Liquid Transport under Wide Humidity Ranges in PEMFC Microporous LayersACS Applied Materials & Interfaces · 2026
- Hydrophilic–hydrophobic flow-field engineering for passive water management in high-power-density PEMFCsFrontiers in Chemistry · 2026
- Gradient Engineered Microporous Layers for Enhanced Oxygen Transport in PEM Water ElectrolysisACS Energy Letters · 2026
- Molecular Engineering of Membrane Electrode Assemblies With Superior Humidity Robustness for Fuel Cells.Small (Weinheim an der Bergstrasse, Germany) · 2026