ACS Applied Electronic Materials

MXene-Assisted Glycine Crystallization and Enhanced Piezoelectric Response in Chitosan–Glycine/Ti3C2T z Composites

Katarina Vojisavljević, Hana Uršič, Nejc Suban, Ivana Goričan, Milica Počuča-Nešić, Slavica Savić Ružić, Zorica Marinković Stanojević, Mirjana Vijatović Petrović,

Key points

From the paper's conclusion
  • Overall, the developed approach provides a strategy for engineering bio-based piezoelectric sensing materials through glycine composition selection and MXene incorporation, offering potential for wearable pressure and motion-monitoring applications.

Abstract

Growing demand for flexible, lightweight, and highly sensitive pressure sensors for wearable electronics motivates research of biopolymer-based piezoelectric materials. However, achieving controlled electromechanical performance through material design remains a challenge. This study reports a flexible, bio-based piezoelectric hybrid composite consisting of a degradable chitosan–glycine (CH–Gly) matrix with Ti3C2Tz MXene. The CH/Gly ratio dictates the growth of glycine crystals and their polymorphic evolution to the desired piezoelectric and/or ferroelectric γ- and β-phases and consequently governs the development of the piezoelectric functionality of the composite. The chitosan–glycine composition with a CH/Gly weight ratio of 1:0.6 (CH–0.6Gly) exhibits a dense spherulitic structure consisting of β- and γ-phases, while MXene incorporation is associated with further changes in glycine phase composition and crystal morphology. After poling, a pressure sensor incorporating CH–0.6Gly–MXene as an active material generated an output voltage of 1.96 V by finger pressing and exhibited a pressure sensitivity of 11.8 mV·kPa–1 at 1 Hz. Furthermore, the sensor effectively transduced slow and continuous musculoskeletal movements, with its response evaluated at different elbow and finger bending angles. At full flexion, output voltages of ∼2.40 and ∼0.82 V were recorded for elbow and finger bending, respectively. These results demonstrate the capability of the CH–0.6Gly–MXene composite to convert mechanical pressure and musculoskeletal motion into electrical signals. Overall, the developed approach provides a strategy for engineering bio-based piezoelectric sensing materials through glycine composition selection and MXene incorporation, offering potential for wearable pressure and motion-monitoring applications.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers