Coupled Transport-Capture in Aligned ZIF-8/Polyacrylonitrile Electrospun Fibrous Membranes: In-Line Hemoglobin Removal for Enzymatic and pH-Responsive Colorimetric Test Strips.
Paranee Phuking, Pairayaphak Ngamplang, Dzul Fadli Alimin, Piyachat Chuysinuan, Pitt Supaphol
The Petroleum and Petrochemical College, Chulalongkorn University, Bangkok10330, Thailand. · Laboratory of Organic Synthesis, Chulabhorn Research Institute, Bangkok10210, Thailand.
Key points
From the paper's conclusion- We report a proof-of-concept test strip in which a separation pad capturing Hb in-line during capillary flow is coupled to downstream colorimetric detection pads.
Abstract
Hemoglobin (Hb) interferes with colorimetric assays because its strong visible absorption masks the chromogenic signal. We report a proof-of-concept test strip in which a separation pad capturing Hb in-line during capillary flow is coupled to downstream colorimetric detection pads. The separation pad is an aligned electrospun polyacrylonitrile membrane bearing in-situ-grown zeolitic imidazolate framework-8 (ZIF-8). Although the as-spun mats show apparent water contact angles of 110-128°, all wick Hb solution laterally; a two-barrier wetting analysis attributes the apparent nonwetting to the outermost fiber layer and indicates that fiber alignment accelerates transport mainly by lowering this entry barrier. Increasing the Zn2+ precursor concentration from 100 to 400 mM raises the 90 min Freundlich constant for Hb 2.6-fold, whereas bovine serum albumin is not measurably depleted, and the framework remains intact after Hb exposure, indicating Zn2+-mediated affinity at the external ZIF-8 surface. The same loading lowers permeability and narrows the operating window under flow from 80 to 20 mg mL-1 Hb; the 200 mM formulation combines 42% more capacity than the 100 mM formulation with a 17% lower intrinsic flow rate and generates filtrate up to 40 mg mL-1 Hb. Integrated with pyrrolidonyl arylamidase and oxidase pads for necrotizing fasciitis triage and with an m-cresol purple pad for meat-spoilage monitoring, the separation pad preserved 74-126% of the stand-alone colorimetric signal at matched bacterial load or pH in Hb-spiked simulated samples. Undiluted whole blood lies outside the present operating window, and validation with real samples remains to be performed.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Starch-ZnAl Layered Double-Hydroxide Nanocomposites and PVDF Membrane Nanofillers for the Sustainable Recovery of Dye-Contaminated Water.Polymers · 2026
- Heparinization of anodized aluminum oxide (AAO) membranes for affinity separations of biocolloids.RSC advances · 2026
- Synergistic effects of combining ZIF-8 and graphene oxide inside cellulose acetate-based mixed matrix membranes on the removal of methylene blueCase Studies in Chemical and Environmental Engineering · 2026
- Zinc oxide-coated coconut shell biochar-filled polylactic acid composite membranes for methylene blue removal from aqueous solutions.RSC advances · 2026
- Adsorptive removal of the cationic dye malachite green from wastewater with an anionic hydrogel.RSC advances · 2026
- Fabrication of Electrospun PAN/ZnO Nanofibers for Photocatalytic Degradation of Methylene Blue under UV IrradiationEPJ Web of Conferences · 2026