Divergence in Cu(II)- and Zn(II)-Based Coordination Polymers: The Sensing of Melatonin and Tryptophan, and Their Anticancer Activity
Koushik Saha, Sunandita Bhar, Narayan Ch. Jana, Nayim Sepay, Basudeb Dutta, Sudeep Ranjan Jana, Arpita Chandra, Chittaranjan Sinha
Jadavpur University · Chittaranjan National Cancer Institute
Key points
From the paper's conclusion- Cu(II)- and Zn(II)-based coordination polymers (CPs) have been designed in this work to detect trace levels of melatonin and tryptophan and evaluate their anticancer activity.
Abstract
Accurate and selective recognition of ions and molecules is crucial in medical and diagnostic research. Cu(II)- and Zn(II)-based coordination polymers (CPs) have been designed in this work to detect trace levels of melatonin and tryptophan and evaluate their anticancer activity. The [Cu 2 (4-bph) 2 (adc) 4 ] n (CP1) (4-bph = (1E,2E)-1,2-bis(pyridin-4-ylmethylene) hydrazine; Hadc = 1-adamantanecarboxylic acid) structure shows that 4-bph serves as a bridging pyridyl-N ligand and adc – is a chelating and binuclear bridging ligand, forming an eight-membered Cu(μ-COO) 2 Cu motif. In Zn(II)-CP, 4-bph is a bridging ligand, while adc – is monodentate, yielding [Zn(4-bph)(adc) 2 ] n ( CP2 ). In CP1, π–π stacking (∼3.875 Å) and hydrogen bonding generate a 3D supramolecular network while CP2 forms pyridyl-N bridging zigzag 1D CP. The BET analysis measures higher pore volume of CP1 (0.06 cm 3 g –1 ) than CP2 (0.018 cm 3 g –1 ). The CP1 is weakly emissive, and upon irradiation at 312 nm, it emits at 392 nm which has been enhanced by the addition of tryptophan (Trp) (LOD, 44.65 nM), in the presence of 19 other amino acids. The CP1 senses melatonin (MEL) (LOD, 38 nM) also in the presence of various proteins, enzymes, and neuroactive metal ions. Blood serum is used for the measurement of melatonin in blood serum (pH 7.4) and also tryptophan measurement in milk. The CP2 is inactive toward sensing performance. DFT computation using crystallographic parameters reveals a stronger binding of CP1 with Trp (−221 kcal mol –1 ) than that of CP2 (−38.22 kcal mol –1 ). Anticancer assays show that CP1 is more potent than CP2 against MCF-7 breast cancer cells, IC 50 values are 196.8 ± 2.31 nM ( CP1 ) and 258.2 ± 2.08 nM ( CP2 ). Both CPs exhibit minimal toxicity toward normal PBMCs at these doses. Theoretical evaluation has also been used to explain the luminescence and selective sensing behavior to Trp and MEL.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- A Novel Co(II) Coordination Compound Fluorescent Probe for Visual, Rapid, and Selective Detection of Hydrazine HydrateCrystal Growth & Design · 2026
- Distinct Structures, Luminescence, and Sensing Performance for Coordination Polymers Achieved by Isomeric Bispyridinyl-Triphenylamine LigandsCrystal Growth & Design · 2026
- Copper (II) Based Metal‐Organic Compounds for Selective Detection of Tumor Biomarker Glutathione, Cysteine, and Homocysteine by Perceiving Luminescence Turn‐OnChemistrySelect · 2026
- A multifunctional bishydroxycoumarin conjugate exhibiting AIE characteristics and tandem Co2+/ATP detection with logic gate operations, on-site sensing and bioimaging applications.RSC advances · 2026
- Tetrazole-based fluorescent probe for sensitive detection of Cu2+: photoluminescence, biological activity, DNA/BSA interaction, and theoretical insightsResults in Chemistry · 2025
- Synthesis, spectroscopic and DFT investigation of a dual-fluorophore methylene blue-naphthalimide probe for selective Cu2+ ions sensing and HeLa cell imaging.Spectrochimica acta. Part A, Molecular and biomolecular spectroscopy · 2026