Microdroplet Phase Change Leads to Substantial Variation in Exhaled Breath Condensate Sampling.
Amio Pronoy Das Ritwik, Yamin Mansur, Yiming Thomas Lu, Jingcheng Ma
Department of Aerospace and Mechanical Engineering, University of Notre Dame, Notre Dame, Indiana46556, United States.
Key points
From the paper's conclusion- Together, these findings establish a basis for characterizing EBC physical measurement variability and provide an actionable path toward EBC's clinical deployment.
Abstract
Exhaled breath condensate (EBC) has been proposed as a promising non-invasive diagnostic biofluid for 50 years, yet no EBC-based test has reached clinical deployment. A major barrier to clinical translation is its measurement variability, which can span orders of magnitude, far exceeding the 10% clinical tolerance. Whether this variability originates from human biology or physical measurement error remains unknown. To separate these contributions, we examined how EBC biomarkers are transported during the condensation and evaporation of EBC droplets, a physical process common to all EBC samplers. Contrary to the previous assumption that biomarkers accumulate steadily, we found that microscale droplets can lose significant volatile content within each breath cycle and generate substantial cumulative measurement errors. We further developed physical models to quantify EBC biomarker transport. Together, these findings establish a basis for characterizing EBC physical measurement variability and provide an actionable path toward EBC's clinical deployment.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Bioinspired Face Mask for Exhaled Breath Condensate Collection and Multiplexed Biomarkers AnalysisACS Nano · 2025
- Condensation sampling integrating molecular recognition enrichment for human exhaled breath condensate metagenomicsFrontiers in Microbiology · 2026
- Assessment of Immune and Proteomic Markers in Exhaled Breath Condensate: A Feasibility Study.Environment & health (Washington, D.C.) · 2026
- Exhaled Breath Analysis for Lung Cancer Detection: From VOCs Signatures to EBC-Based Liquid Biopsy and Clinical Translation.Thoracic cancer · 2026
- Amino acid profiles in exhaled breath condensate: evaluation of collection methods and diurnal variation Using LC-MS/MS.Journal of breath research · 2026
- Bioinspired Wettability Engineering Enables Efficient Exhaled Breath Condensate Harvesting for Wearable Respiratory Monitoring.ACS sensors · 2026