Aptamer-Modified Extended-Gate Field-Effect Transistor Allows Direct Detection of Minute Cell Surface Charge for Early Diagnosis of Leukemia.
Toshiya Sakata, Sota Tatemichi, Amer Akao
Department of Materials Engineering, School of Engineering, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo113-8656, Japan.
Key points
From the paper's conclusion- In this study, we have demonstrated a direct electrical detection of leukemia cells such as CCRF-CEM using an extended-gate field-effect transistor (FET) sensor modified with the sgc8c aptamer.
Abstract
A miniaturized and inexpensive biosensor should be developed for the early and rapid diagnosis of leukemia. In this study, we have demonstrated a direct electrical detection of leukemia cells such as CCRF-CEM using an extended-gate field-effect transistor (FET) sensor modified with the sgc8c aptamer. As a result, we found that the FET signal intensity quantitatively increased with cell density, resulting from CCRF-CEM cell-sgc8c aptamer-specific interactions. In particular, the increase in the amount of the sgc8c aptamer immobilized on the gate electrode contributed to the increase in cell density on it, resulting in quantitative detection of CCRF-CEM cells on the gate electrode. Moreover, the surface charge of a CCRF-CEM cell was analyzed in accordance with the detection principle of FET sensors. Indeed, slight changes in molecular charges on CCRF-CEM cells that would have entered the Debye screening layer were detected owing to the amplification of electrical signals by the capacitive gate structure in the front-end junction-type FET system, which was composed of the extended-gate FET sensor in this study. The analysis further suggests that only a limited fraction of the cell surface charge near the gate interface contributes to the FET response.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Small‐Molecule Probes Enhance in Vivo Field‐Effect Transistor‐Based Biosensing by Overcoming Debye Length LimitationsAngewandte Chemie International Edition · 2025
- Biochemical Interface Engineering for Transistor-Based Point-of-Care DiagnosticsAccounts of Chemical Research · 2026
- Aptamer-Functionalized Microchannel-Gated Field-Effect Transistor Biosensor for In Vivo Detection of DopamineAnalytical Chemistry · 2026
- Field-effect transistor biosensors for biomedical applications: material platforms, interfacial engineering, and translational challenges.Mikrochimica acta · 2026
- Operational Flaws in Field-Effect Transistor (FET)-Based Biosensors: Gate-Leakage Current in Water-Gate FET Devices and Fake Field-Effect Signals from Biomolecular ChargeBiosensors · 2026
- Cell Spreading-Enhanced Electron-Transfer Electrochemical Cytosensor Enabling Single-Cell DetectionNature Communications · 2026