Langmuir : the ACS journal of surfaces and colloids

Study on the Selective Fluorescent Detection of Tetracycline, Cr6+, and Ethylene Glycol Using Nitrogen- and Phosphorus-Co-Doped Carbon Dots.

Jingmei Lu, Na Zheng, Jikun Shen, Meng Zhang, Zhaoyu Ma, Ju Tang, Fan Zhang, Guo Chen

Kunming Key Laboratory of Energy Materials Chemistry, Yunnan Minzu University, Kunming, Yunnan650093, P. R. China.

Key points

From the paper's conclusion
  • As fluorescent probes, their sensing performance toward Cr6+, tetracycline (TC), and ethylene glycol (EG) was systematically investigated.

Abstract

In this work, two types of nitrogen- and phosphorus-co-doped carbon dots (N,P1-CDs, N,P2-CDs) were successfully prepared via a solvothermal method at 180 °C for 6 h, employing o-phenylenediamine and phosphoric acid, as well as 2-aminoterephthalic acid and phosphoric acid, as the respective precursors. Characterizations including X-ray diffractometer, transmission electron microscope, X-ray photoelectron spectrometer, FT-IR, and zeta potential verify the successful co-doping of nitrogen and phosphorus. The zeta potentials of N,P1-CDs and N,P2-CDs are 8.04 mV and 7.12 mV, with corresponding fluorescence quantum yields of 11.38 and 13.2%, respectively. Both CDs exhibit outstanding pH tolerance and long-term fluorescence storage stability. As fluorescent probes, their sensing performance toward Cr6+, tetracycline (TC), and ethylene glycol (EG) was systematically investigated. Both CDs realize quantitative detection of Cr6+ within the concentration range of 5-140 μg/mL with distinct recognition selectivity: N,P2-CDs display superior performance for TC detection, while N,P1-CDs can specifically recognize EG. All sensing systems exhibit favorable linearity and relatively low limits of detection (LOD), among which the LOD of N,P1-CDs toward EG reaches only 0.1052 μM. Coexisting ion experiments prove the favorable anti-interference capacity of the two probes, and N,P2-CDs possess better stability. Satisfactory detection results are achieved in spiked real water matrices including tap water and river water, where the fluorescence quenching efficiencies for Cr6+ all exceed 93%. Mechanism analysis reveals that the detection of Cr6+ by N,P-CDs follows the photoinduced electron transfer pathway. The fluorescence quenching triggered by EG and TC originates from the synergistic effect of hydrogen bonds and inner-filter effect. The dual CDs system enables simultaneous multitarget detection of heavy metals, antibiotics, and organic solvents, which broadens the application prospects of carbon-based fluorescent materials in environmental pollutant monitoring.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers