Calibration of Passive Sampling Eyewear to Assess Inhalation Exposure.
Jenny Li-Liao, Isabella Pastore, Sara Vaezafshar, Camille Tsang, Anya Guo, Joseph O Okeme
Department of Chemistry & Chemical Biology, McMaster University, L8S 4L8Hamilton, Ontario, Canada.
Key points
From the paper's conclusion- Overall, the findings from both the calibration and field studies represent a significant step toward quantitatively assessing inhalation exposure using PSE.
Abstract
Calibrated wearable passive air samplers are critical tools for accessibly quantifying individualized and population exposures to airborne pollution, a leading cause of chronic disease. Our lab recently introduced passive sampling eyewear (PSE) to address gaps in tools tailored for measuring and mitigating risks from inhalation exposure. The PSE, like most existing designs of wearable samplers, is largely uncalibrated. An exception is the polydimethylsiloxane (PDMS) brooch, and mini-polyurethane foam (PUF) samplers, which have been calibrated for only 27 compounds. Here, we calibrate PSE against active air samplers codeployed in both stationary and wearable forms in office and home environments to capture a wide range of exposure scenarios. We report sampling rates (RS) and inhalation exposure for over 200 features covering diverse physical-chemical properties measured using the Orbitrap gas chromatography coupled to mass spectrometry (GC-MS) system in both targeted and nontargeted modes. RS were 0.70 ± 0.62 m3 day-1 dm-2 for stationary and 0.85 ± 0.68 m3 day-1 dm-2 for wearable deployments, with no significant difference (p = 0.06) between the deployment types. Wearable calibration captured higher RS and variability, as expected for personal sampling, because participants' movement and daily activity can alter airflow and disrupt the stagnant air-boundary layer around the sampler. In terms of analysis mode, RS derived from targeted and nontargeted analysis (NTA) were reasonably comparable for a given compound, differing by ∼1.5-fold, boosting confidence in using NTA approaches for expanding databases of RS. Applying the wearable RS, the profiles and levels of inhalation exposure varied widely between participants when at home versus in offices, reflecting differences in exposure sources and dynamics between the two environments. Overall, the findings from both the calibration and field studies represent a significant step toward quantitatively assessing inhalation exposure using PSE.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Comparative Assessment of Personal Exposures to Environmental Contaminants Using Silicone Wristbands and Fresh Air Wristbands.Environmental science & technology · 2026
- Integrated Approach for Comprehensive Screening of Indoor Semi-Volatile Organic Compounds via Passive Air Sampling Coupled with Non-targeted AnalysisEnvironmental Science & Technology · 2025
- Behavior-weighted wearable passive sampling of personal airborne phthalate exposure among university students.Environmental pollution (Barking, Essex : 1987) · 2026
- AirComm: Your Smartphone Can “Smell” Fine Particles via LightProceedings of the ACM on Interactive, Mobile, Wearable and Ubiquitous Technologies · 2026
- Silicone-Foam Passive Air Samplers for Combined Target and Nontarget Chemical Profiling and Toxicity Assessment of Airborne ExposomesEnvironmental Science & Technology · 2026
- Methodological Assessment of PDMS Passive Sampling for Skin VOC Collection Across Body Sites.Metabolites · 2026