A Continuous Virus Aerosol-into-Liquid Sampler (VAiLS) Integrating Twin-Vortex Condensation Growth and Wet-Cyclone Enrichment.
Jae Hak Shin, In Ho Kim, Sang Bin Jeong, Sang Bok Kim, Jae Hee Jung
Department of Mechanical Engineering, Sejong University, Seoul05006, Republic of Korea. · Department of Urban Environment Research, Korea Institute of Machinery and Materials, Daejeon34103, Republic of Korea.
Key points
From the paper's conclusion- Here, we develop a continuous Virus Aerosol-into-Liquid Sampler (VAiLS) that integrates a twin-vortex condensation growth unit (CGU) with a wet cyclone (w-Cyc) to enlarge virus-sized aerosols into micrometer droplets and continuously concentrate them into a hydrosol sample, defined here as the particle-containing aqueous suspension produced by transferring aerosol particles into the w-Cyc liquid f
Abstract
Airborne virus surveillance requires sampling methods that efficiently transfer nanoscale virions into a small-volume liquid while preserving infectivity. Here, we develop a continuous Virus Aerosol-into-Liquid Sampler (VAiLS) that integrates a twin-vortex condensation growth unit (CGU) with a wet cyclone (w-Cyc) to enlarge virus-sized aerosols into micrometer droplets and continuously concentrate them into a hydrosol sample, defined here as the particle-containing aqueous suspension produced by transferring aerosol particles into the w-Cyc liquid film. The CGU combines a low-temperature preconditioner (∼5 °C) with a wick-wetted growth chamber (Tg = 20-60 °C) to generate supersaturation at a high sampling flow rate (16 L/min), and the downstream w-Cyc collects the grown droplets via a stable liquid film. Using KCl nanoparticles as model aerosols, the number-weighted total collection efficiency increased from 7.3% (w-Cyc only) to 31.0, 64.4, and 70.4% at Tg = 20, 40, and 60 °C, respectively, with no appreciable dependence on inlet relative humidity (16.8-71.8%). For airborne viruses, VAiLS achieved maximum collection efficiencies at Tg = 40 °C (MS2: 93 ± 0.6%; phi 6: 90 ± 2.1%) and produced much higher infectious concentrations than a BioSampler (3.9 × 103-fold for MS2 and 1.2 × 103-fold for phi 6). Relative virus viability remained >92% for most conditions, decreasing only for phi 6 at Tg = 60 °C (5.8 ± 4.37%). These results demonstrate that VAiLS enables high-flow, high-enrichment, infectivity-preserving sampling compatible with plaque assays and qPCR.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Ultrarapid Collection of High-Concentration Viral Samples from Small-Volume Exhaled Breath for Respiratory Virus SurveillanceAnalytical Chemistry · 2026
- Evaluation of the Collection Efficiency of a Wet-Type Electrostatic Precipitator for Aerosolized Influenza A Virus.Microorganisms · 2026
- Linear predictive model of viral load from air samples in simulated conditions.Journal of occupational and environmental hygiene · 2026
- Spiral Microchannel-Based Chip for Virus Monitoring Using Localized Air Sampling.Biosensors · 2026
- Evaluation of Two Cyclonic Bioaerosol Samplers for Hospital Air Monitoring in a Calibrated Test Chamber Integrating Aerodynamics and Biological EndpointsIndoor Air · 2026
- Validation of a standardized quantitative RT-qPCR workflow for detection and quantification of airborne respiratory viruses using gelatin membranes as sampling matrix.Journal of microbiological methods · 2026