Optimization and Testing of an SPE-LC/q-TOF Analytical Method for the Detection of PFAS Degradation Products in Water Treatment Processes
Giulia Tomei, Elena Piva, Mubbshir Saleem, M Finotto, Michele Pozzebon, Ester Marotta
University of Padua · Quanta System (Italy)
Key points
From the paper's conclusion- Solid-phase extraction and LC-ESI/q-TOF parameters have been optimized to maximize recovery and detection of PFOS, PFOA, shorter-chain PFCAs, and various polyfluoroalkyl and polyfluorohydroxyalkyl carboxylic/sulfonic acids obtained in the treatment of solutions 1.0 × 10 –6 M PFOA or PFOS in tap water by nonthermal plasma (NTP).
Abstract
High Resolution Image Download MS PowerPoint Slide The research on novel methods for water treatment to achieve the degradation of perfluoroalkyl and polyfluoroalkyl substances (PFAS) is very active and usually considers perfluorooctanoic acid (PFOA) and perfluorooctansulfonic acid (PFOS) to test the process efficacy. Their degradation generally proceeds through the sequential formation of shorter-chain perfluoroalkyl carboxylic acids (PFCAs), which are detected and quantified by means of well-established methods. However, hydro- and hydroxy-defluorinated products of various chain length, in which one or more –F atoms have been substituted by −H atoms and/or –OH groups, can be formed as well. An analytical method was therefore developed, capable of concentrating and simultaneously analyzing PFCAs and these substitution products. Solid-phase extraction and LC-ESI/q-TOF parameters have been optimized to maximize recovery and detection of PFOS, PFOA, shorter-chain PFCAs, and various polyfluoroalkyl and polyfluorohydroxyalkyl carboxylic/sulfonic acids obtained in the treatment of solutions 1.0 × 10 –6 M PFOA or PFOS in tap water by nonthermal plasma (NTP). The application of the developed analytical method, which was tested on real groundwater samples contaminated with PFAS and treated with NTP, is suggested for studies dealing with advanced reduction/oxidation processes for PFAS removal to verify the absence of polyfluoroalkyl and polyfluorohydroxyalkyl carboxylic/sulfonic acids.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Evaluation of Perfluorooctanoic Acid (PFOA) Degradation in Synthetic Water Using Advanced Oxidation Processes Based on O3, H2O2, and UV LightMolecules · 2026
- Efficient and low-energy degradation of PFAS in complex waters via enhanced hydrated electron generation using a VUV/sulfite processJournal of Water Process Engineering · 2026
- Targeted and Non‐Targeted Analysis of Novel and Legacy Per and Polyfluoroalkyl Substances in River Water by Direct Analysis in Real Time Mass SpectrometryRapid Communications in Mass Spectrometry · 2026
- Ultrasonic Oxidative Treatment of Per- and Polyfluoroalkyl Substances (PFAS) in Aqueous Film-Forming Foams and Foam-Derived WastewatersProcesses · 2026
- Perfluoroalkyl chain-length-dependent environmental fate and treatment outcomes of PFAS in waternpj Clean Water · 2026
- Strategies for Enhanced Photoreductive Degradation of Per- and Polyfluoroalkyl Substances (PFAS) in Wastewater.Environmental research · 2026