Analytical chemistry

Portable Split-Type Photoelectrochemical Immunosensing of TBBPA via Enzymatic Amplification and Double S-Scheme Signal Transduction.

Mingdi Xu, Yanxin Lin, Xiaonan Feng, Zhimin Fan, Kun Zhang, Miao Chen, Zheqian Chen, Jingjing Yao,

School of Urban and Environmental Engineering, Fujian University of Technology, Fuzhou350108, China. · Shenzhen Key Laboratory of Precision Measurement and Early Warning Technology for Urban Environmental Health Risks, School of Environmental Science and Engineering, Southern University of Science and Technology, Shenzhen518055, China.

Key points

From the paper's conclusion
  • Here, we report a split-type photoelectrochemical (PEC) immunosensing platform that spatially separates competitive immunorecognition and glucose oxidase (GOx)-mediated H2O2 generation from PEC transduction.

Abstract

Tetrabromobisphenol A (TBBPA) is an environmentally relevant brominated flame retardant that requires rapid, low-cost, and field-deployable monitoring tools, yet existing sensor-based methods remain limited by matrix interference, insufficient sensitivity, or poor compatibility with portable analysis. Here, we report a split-type photoelectrochemical (PEC) immunosensing platform that spatially separates competitive immunorecognition and glucose oxidase (GOx)-mediated H2O2 generation from PEC transduction. A double S-scheme ZnO@g-C3N4@BiOIO3 heterojunction on a screen-printed electrode serves as the H2O2-responsive photoactive interface. Band-structure analysis, light/dark XPS, open-circuit photovoltage, and charge-dynamics measurements support built-in electric field-assisted directional carrier separation across the coupled heterointerfaces, accounting for the enhanced cathodic PEC response. Target-dependent competition regulates GOx-labeled probe retention and H2O2 production, converting TBBPA concentration into attenuation of the photocurrent. The sensor exhibits a linear range of 5-5000 pM with a detection limit of 0.67 pM (0.36 ng L-1), together with good reproducibility, selectivity, and tolerance to representative matrix interferents. Direct analysis of filtered river-water samples without preconcentration yields recoveries of 91.75-110.90% relative to UPLC-MS/MS. Integration with a smartphone-compatible portable potentiostat and disposable SPE format enables low-cost field-oriented analysis. This recognition-amplification-transduction architecture provides a practical strategy for sensitive and matrix-tolerant TBBPA screening in environmental waters.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers